Manual de Instruções para
Bomba de Porão Cartridge Johnson Pump
Em caso dúvidas na instalação após a leitura do manual, favor entrar em
contato com nosso departamento técnico através do telefone ou email:
• (11) 3477-5655�
• email: [email protected]
Horários de atendimento:
Segunda-feira à quinta-feira: 8h – 18h
Sexta-feira: 8h – 17h
Rua Anhaia 982, Bom Retiro – SP
www.marineoffice.com.br
I N STR UCTION MAN UAL
OR IG I NAL I N STR UCTION S /TRAN S LATION OF OR IG I NAL I N STR UCTION S R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR
S E RVICI NG TH I S PROD UCT
Submersible Bilge Pumps CARTR I DG E L-S E R I E S L450, L550, L650, L750
I B-103 R06 (01/2016)
6 Original instructions
> English
��.PV
OU�JO
�UIF�MPXFTU�
�QP
JOU�P
G�UIF
�CJMHF
��'P
S�MPO
HFS�Q
VNQ�MJGF �
�EP
�OPU�SV
O�ESZ
Low
est l
evel
for s
uctio
nM
easu
re "A
"L4
50/5
00 –
8 m
mL5
50/7
50 –
8 m
mL6
50/1
000
– 8
mm
L750
/125
0 –
8 m
mA
Des
ign
feat
ures
(EU
) L4
50
L550
L6
50
L750
(U
SA)
50
0 75
0 10
00
1250
Hos
e si
ze
3/4"
3/
4"
3/4"
1.
1/8"
Cap
acity
, stra
ight
(13.
6 V)
40
l/m
in/6
30 G
PH
50 l/
min
/800
GPH
63
l/m
in/1
000
GPH
73
l/m
in/1
150
GPH
Cap
acity
, 1 m
hea
d (1
3.6
V)
33 l/
min
/525
GPH
44
l/m
in/7
00 G
PH
50 l/
min
/800
GPH
60
l/m
in/9
52 G
PH
Volta
ge
12 V
DC
12
V D
C
12 V
DC
12
V D
CAm
pera
ge
2,5
A 3
A 3.
2 A
3 A
Fuse
size
5
A 5
A 5
A 5
AH
eigh
t 11
2 m
m
112
mm
11
2 m
m
112
mm
Max
dia
70
mm
70
mm
70
mm
70
mm
Wei
ght
0.27
kg
0.27
kg
0.27
kg
0.32
kg
Bod
y Th
erm
opla
stic
Th
erm
opla
stic
Th
erm
opla
stic
Th
erm
opla
stic
Shaf
t sea
l Li
p se
al
Lip
seal
Li
p se
al
Lip
seal
Wire
size
0.
75 m
m2
0.75
mm
2 0.
75 m
m2
0.75
mm
2
Type
des
igna
tion
Pum
p ty
pe (E
U)
L450
– 1
2 V
L550
– 1
2 V
L650
– 1
2 V
L75
0 –
12 V
Art n
o32
-145
0-01
32-1
550-
01
32
-165
0-01
32-1
750-
01Pu
mp
type
(USA
)50
0 G
PH75
0 G
PH10
00 G
PH12
50 G
PHAr
t no
3250
332
703
3290
342
123
7Original instructions
> English
INSTALLATION Please follow the installation instructions carefully to assure maximum efficiency in your bilge pump operation.1. Mount the pump in the lowest
point of the bilge. 2. Select a point where the
bilge water is to be pumped overboard as high as possible above the water line and at the shortest distance from the pump. Install a 3/4" thru-hull fitting (L750/1250 – 1.1/8").
3. Fasten a 3/4" (L750/1250 – 1.1/8") fuel resistant hose from the pump outlet to the thru-hull fitting. Avoid sharp bends or loops. Support the hose if necessary. Note: In order to prevent air lock is important that the hose not be allowed to dip below the pump outlet. The hose should be constantly rising.
Electrical installation1. Connect the brown wire to
the positive (+) terminal of the battery.
2. Connect the black wire to the negative (-) terminal of the battery.
3. Do not cut back insulation more than necessary. Insulation or cable sheathings have to be removed in such a way that they end well above the highest bilge water level. The wire connections should be sealed with a marine sealant to prevent wire corrosion.
To remove or replace power cartridge4FF�QBHF���1. Lift tab and rotate the two fins
in a counter clockwise direction and lift out.
2. To reinstall, first make sure that the seal is properly located. Coat the seal with a light film of vegetable oil or mineral oil, then align the two cams on either side of the power cartridge with the two slots in the outer housing. Press down and twist in a clockwise rotation. To ensure that the power cartridge is properly located, twist tins in a counter clock-wise direction without lifting tab. Cartridge should stay in place.
8 Original instructions
> English
ACCESSORIESAutomatic Switch AS888Part No. 34-888/26014The automatic switch AS888 protects electrically operated pumps and gives fully automatic operation. The AS888 is made of corrosion resistant materials.
Panel 12 or 24 VPart No.12 V – 34-1224/8204424 V – 34-1225/82044-24The panel combined with automatic switch AS888 is an excellent installation for your boat.
Installation SPX FLOW Johnson Pump submersible bilge pump/automatic switch AS888/ Panel4FF�QBHF���Always install switch AS888, panel and fuses between the positive (+) terminal of the battery and the positive (+) connection of the pump (brown wire). The negative (-) connection (black wire) of the pump to be connected directly to the negative (-) terminal of the battery. Fuse size applies to pump specification.
Electronic Float SwitchPart No. 34-1900 B/36152 – 12 V 34-1900 B/36252 – 24 V The electronic float switch is the same switch as on Cartridge Duo. As a separate accessory it is possible to attach the switch to all pumps in the SPX FLOW Johnson Pump L-serie.
Waste handling/ material recyclingAt the products end of life, please dispose of the product according to applicable law. Where applicable, please disassemble the product and recycle the parts material.
21
-ZGU�MlTIBLFO-JGU�UBC%JF�;VOHF�IFCFO4PVMFWFS�MB�MBOHVFUUF-FWBOUBS�MB�MFOH�FUB-FWBSF�MB�MJOHVFUUB
.POUFSB3FJOTUBMM.POUJFSFO3FNPOUFS.POUSBS3JNPOUBSF
%FNPOUFSB3FNPWF&OUGFSOFO&OMFWFS2VJUBS3JNVPWFSF
5jUOJOH4FBM%JDIUVOH+PJOU+VOUB(VBSOJ[JPOF
22
Elektrisk intsallation med panelElectrical installation with PanelElektrischer Anschluss mit SchalttafelSchéma de raccordement avec le tableau de commandeInstalación eléctrica con panelSchema collegamento elettrico con pannello di controllo
�%$�TVQ
QMZ���#
BUUFSJF
DC
-Ver
sorg
ung
���#
BUUFSJB
���#BUFSrB
Bat
teri
B
row
n
Mar
ron
B
raun
M
arro
ne
Mar
rón
B
run
Auto
mat
ic S
witc
h AS
888
(+) b
row
n pu
mp
lead
(+
) fil m
arro
n de
la p
ompe
(+) b
raun
er P
umpe
leite
r(+
) pom
pa c
avo
mar
rone
(+) c
ondu
ctor
bom
ba m
arró
n(+
) bru
n pu
mpk
abel
(-) b
lack
pum
p le
ad(-
) fil n
oir d
e la
pom
pe(-
) sch
war
zer P
umpe
leite
r(-
) pom
pa c
avo
nero
(-) c
ondu
ctor
bom
ba n
egro
(-) s
vart
pum
pkab
el
2 B
ilge
pum
p
Pom
pe d
e ca
le
B
ilgen
pum
pe
Pom
pa d
i sen
tina
B
omba
de
sent
ina
Lä
nspu
mp
Not
e: T
his
cabl
e is
alre
ady
conn
ecte
dIm
port
ant:
Ce
câbl
e es
t déj
à co
nnec
téW
icht
ig: K
abel
ist b
erei
ts v
erbu
nden
Not
a B
ene:
Que
sto
cavo
é g
ià c
olle
gato
Adve
rten
cia:
Est
e ca
ble
ya e
stá
cone
ctad
oO
bs: D
enna
kab
el ä
r red
an a
nslu
ten
1 Pa
nel
Ta
blea
u de
com
man
de
Scha
lttaf
el
Pann
ello
Ta
bler
o
Pane
l
23
Elektrisk intsallation utan panelElectrical installation without panelElektrischer Anschluss ohne SchalttafelSchéma de raccordement sans tableau de commandeInstalación eléctrica sin panelSchema collegamento elettrico senza pannello di controllo
1. Länspump Bilge pump Bilgenpumpe Pompe de cale Bomba de sentina Pompa di sentina
(-) svart pumpkabel(-) black pump lead(-) schwarzer Pumpeleiter(-) fil noir de la pompe(-) conductor bomba negro(-) pompa cavo nero
(+) brun pumpkabel (+) brown pump lead (+) brauner Pumpeleiter (+) fil marron de la pompe (+) conductor bomba marrón(+) pompa cavo marrone
Johnson Pump Automatic Switch AS888
#BUUFSJ���%$�TVQQMZ DC-Versorgung #BUUFSJF���#BUFSJB
� %$�TVQQMZ���#BUUFSJF DC-Versorgung� ��#BUUFSJB���#BUFSrB Batteri