12
SEIKO GROUP

SEIKO GROUP

Embed Size (px)

DESCRIPTION

SEIKO GROUP. TG/DTA. 0,1mg de Oxalato de Cálcio. TG/DTA. TG/DTA. Exemplos de Cadinhos. Alumina Alumínio. Platina. TG/DTA. Amostrador Automático. TG/DTA. Automated Stepwise Temperature Control. Sample : CuSO 4 ・ 5H 2 O. TG/DTA. Application of Highway TA. - PowerPoint PPT Presentation

Citation preview

Page 1: SEIKO GROUP

SEIKO GROUP

Page 2: SEIKO GROUP

℃温度800.0600.0400.0200.00.0

TG

%

20.0

0.0

-20.0

-40.0

-60.0

-80.0

-100.0D

TA u

V

20.00

15.00

10.00

5.00

0.00

0.1mg シュウ酸カルシウム0,1mg de Oxalato de Cálcio

TG/DTATG/DTA

Page 3: SEIKO GROUP

Modelo TG/DTA 6200 TG/DTA 6300

Faixa de Temperatura Ambiente ~ 1100°C

Ambiente ~ 1500°C

Tipo de Balança Horizontal Differential Type

Faixa de massa para TG +/- 200mg

Ruído/sensibilidade media para TG

0.1µg/0.2µg

Faixa de medição do DTA +/- 1000µV

Ruído/sensibilidade media para DTA

0.3µV/0.06µV

Taxa de aquecimento 0.01 ~ 100 °C/min

Unidade Automática de Resfriamento

Resfriamento por injeção de ar

Tempo de Resfriamento 1000°C até 50°C em 15 minutos

Material dos Cadinhos de Amostra

Platina, Alumina, Alumínio

Massa Máxima da Amostra 200mg

Atmosfera Ar, Gases Inertes, Vácuo (10¯² Torr)

Amostrador Automático de 30 Posições

Opicional

TG/DTATG/DTA

Page 4: SEIKO GROUP

AluminaAlumínio

Platina

Exemplos de Cadinhos

TG/DTATG/DTA

Page 5: SEIKO GROUP

Amostrador Automático

TG/DTATG/DTA

Page 6: SEIKO GROUP

Sample : CuSO4 ・ 5H2O

Automated Stepwise Temperature ControlAutomated Stepwise Temperature Control

TG/DTATG/DTA

Page 7: SEIKO GROUP

Research & Development Application ー DTG(TG) and DSC peak separation. ( for reaction of different activation energies ) ー Data simulation of measurements that are difficult

such as extremely high ( ex. 106℃/min ) or extremely low heating rates ( ex. 10-3℃/min ) .

Reduced measurement time for Quality Control ー Measurement time → 1/2~1/10

Application of Highway TAApplication of Highway TATG/DTATG/DTA

Page 8: SEIKO GROUP

Measured Data

Separated Peak

Synthetic Peak

Peak SeparationPeak Separation

TG/DTATG/DTA

Page 9: SEIKO GROUP

High and Low Heating Rate SimulationHigh and Low Heating Rate Simulation

< LDPE >

TG/DTATG/DTA

Page 10: SEIKO GROUP

Prepagado para acoplamento em EGA e EGD, como FT-IR, MS, GC/MS

Multiple Thermal AnalysisMultiple Thermal Analysis(Gas Trancefer System)(Gas Trancefer System)

TG/DTATG/DTA

Page 11: SEIKO GROUP

TG of ABS IR Spectrum

TG-FTIR DATA of ABSTG-FTIR DATA of ABSTG/DTATG/DTA

Page 12: SEIKO GROUP

200℃

300℃

310℃MS Spectrum

TG / DTA

50 ℃ ~ 200℃

300 ℃ ~ 310℃

TG-GC-MS Data of Filme de PVCTG-GC-MS Data of Filme de PVCTG/DTATG/DTA