47
PULVERIZADORES COM ASSISTÊNCIA DE AR PAULO ROSA CONSULTOR TÉCNICO [email protected] 51 9643 3676

PAULO ROSA CONSULTOR TÉCNICO [email protected] 51 … · pulverizadores com assistÊncia de ar paulo rosa consultor tÉcnico [email protected] 51 9643 3676

Embed Size (px)

Citation preview

PULVERIZADORES COM ASSISTÊNCIA DE AR

PAULO ROSA

CONSULTOR TÉCNICO

[email protected]

51 9643 3676

-ALVO TRIDIMENSIONAL -DIVERSIDADE DE PRAGAS E PATÓGENOS -ALVO INTERNO E BARREIRA VERDE -RESISTÊNCIA AO DESLOCAMENTO DA GOTA: COLUNA DE AR -GOTAS FINAS E MUITO FINAS, RAPIDA EVAPORAÇÃO

*

pH

7

N

E

U

T

R

A

0 1

4

ÁCIDA ALCALINA

4,5 A 6

IDEAL

Inseticidas

Fungicidas

3,5 a 5,0

IDEAL

Herbicidas

Pós emerg

pH 3,4

pH 6,0

TEBUCONAZOLE

CARBENDAZIM

*

*

PERDA S PRO SOLO

PERDAS POR DERIVA

Field deposit patterns of a diflubenzuron spray mix, after application to apple orchard using an air-blast

sprayer, and a laboratory evaluation of physical properties an atomization characteristics.

In: Journal of Environmental Science and Health, New York, v. 24, n. 4, p. 389-411, 1989

25 a 74 %

*

PERDAS PRO SOLO

PERDAS POR DERIVA

DEPÓSITO E PERDAS DE CALDA EM SISTEMA DE PULVERIZAÇÃO COM TURBOATOMIZADOR EM VIDEIRA.

In: Eng. Agríc., Jaboticabal, v.26, n.2, p.470-477, maio/ago. 2006

48 a 60 %

*

PERDA S PRO SOLO

PERDAS POR DERIVA

MÉTODO PARA MONITORAR PERDAS NA APLICAÇÃO DE AGROTÓXICOS NA CULTURA DE TOMATE

In: Pesq. Agropec. Bras., Brasília, v.34, n.5, p.741-747, maio 1999

24 a 41 %

20 A 39 %

CONCEITO TRV ( TREE ROW VOLUME )

ALT

UR

A

LARGURA

DISTÂNCIA ENTRE

FILAS(m)

TRV (m³/ha)

10.000 / ENTRE FILA(m ) X

ALTURA(m) X

LARGURA(m)

CONCEITO TRV ( TREE ROW VOLUME )

ALT

UR

A

LARGURA

DISTÂNCIA ENTRE

FILAS(m)

TRV (m³/ha)

10.000 /4(m ) X

3,5(m) X

2(m) =

17.500 m³/HA

COMO DETERMINAR O VOLUME DE CALDA:

CADA 1.000m³ TRV --- 20 A 40 LITROS CALDA/Ha

EXEMPLO: TRV 17.500m³

17,5 X 20 = 350 LITROS/HA

17,5 X 40= 700 LITROS/HA

*

Erlei Melo Reis, Tiago Zanatta& Oldemar Sheer

Faculdade de Agronomia e Medicina Veterinária da

Universidade de Passo Fundo

APLICAÇÃO PREVENTIVA , PRODUTO SISTÊMICO ,CONTROLE DE OÍDIO

TESTEMUNHA

1/3 FINAL

COBERTO

DA FOLHA

1/3 BASE

COBERTO

DA FOLHA

COBERTURA

UNIFORME

DA

FOLHA

APLICAÇÃO CURATIVA , PRODUTO SISTÊMICO ,CONTROLE DE OÍDIO

TESTEMUNHA

1/3 BASE

COBERTO

DA FOLHA

COBERTURA

UNIFORME

DA

FOLHA

1/3 FINAL

COBERTO

DA FOLHA

DIÂMETRO DA GOTA

1 GOTA

DIÂMETRO 300 MICRA

8 GOTAS

DIÂMETRO 150 MICRA

52 GOTAS

DIÂMETRO 80 MICRA

GOTAS MENORES TEM MAIOR CAPACIDADE DE COBERTURA DA SUPERFÍCIE FOLIAR

DURAÇÃO DA GOTA

30°C 50% UR

GOTA 80 MICRA ----- 8 SEGUNDOS

GOTA 150 MICRA ---- 37 SEGUNDOS

GOTA 300 MICRA ---- 146 SEGUNDOS

FONTE: Aldemir Chaim ( EMBRAPA )

ATR RED

4 BAR

AJUSTE DA PRESSÃO DE TRABALHO PRESSÃO IDEAL BICOS TIPO CONE 4 A 7 BAR = 60 A 100 psi

Cone 40 graus Cone 60 graus Cone 90 graus

SOARES E COSTA( 2000 ) EMBRAPA VACARIA

DEPÓSITO DE CALDA SOBRE AS FOLHAS DA MACIEIRA

*

- APLICAR A QUANTIDADE ADEQUADA DE INGREDIENTE

ATIVO SOBRE UM ALVO

- OBTER ECONOMIA DE PRODUTO COM PERFEITA EFICIÊNCIA

- A CONTAMINAÇÃO DO MEIO AMBIENTE PELA DERIVA TEM

CAUSADO FREQUENTES CONDENAÇÕES ÀS PULVERIZAÇÕES

- RESÍDUOS DE PRODUTOS QUÍMICOS TEM SIDO

OBSERVADOS EM ÁREAS VIZINHAS AOS TRATAMENTOS

REALIZADOS

- PRAGAS E DOENÇAS ADQUIREM RESISTÊNCIA POR

COBERTURA DE APLICAÇÃO INEFICIENTE OU DESUNIFORME

*PULVERIZAÇÃO ELETROSTATICA

GOTAS CARREGADAS

CARGA ELÉTRICA

APÓS EXPOSIÇÃO CAMPO ELÉTRICO INTENSO

POR POSSUIREM A MESMA

POLARIDADE, NÃO SE CHOCAM NO AR

POR POSSUIREM CARGA ELÉTRICA

SÃO ATRAÍDAS PELA PLANTA

PRINCÍPIOS DO CARREGAMENTO DA GOTA

ÁGUA NORMAL É ELETRONICAMENTE

NEUTRA

AO SER EXPOSTA A UM CAMPO ELÉTRICO

INTENSO PERDE OU GANHA ELÉTRONS

*

SUPERCARREGADOR PRODUZ

CAMPO ELÉTRICO

DE ALTA VOLTAGEM NA BASE DO JATO

DE PULVERIZAÇÃO E CARREGA GOTAS

MAÇÃ

GOTAS COM CARGA

positiva ou negativa

POR POSSUIREM A MESMA

POLARIDADE, NÃO SE CHOCAM NO AR

POR POSSUIREM CARGA ELÉTRICA

SÃO ATRAÍDAS PELA PLANTA

ELETROSTÁTICO

CONVENCIONAL

PULVERIZAÇÕES COM GRANDES VOLUMES DE CALDA, MUITAS GOTAS CAEM ENTRE

OS ESPAÇOS ENTRE AS FOLHAS E ENTRE PLANTAS ATINGINDO O SOLO

A INTENÇÃO DE MOLHAR A PLANTA COM VOLUMES GRANDES E GOTAS GRANDES

FAZ COM AS GOTAS SE AGRUPEM E ESCORRAM ATINGINDO O SOLO

DESSA FORMA, A RETENÇÃO DE PRODUTO QUÍMICO É MENOR PELA FOLHA

QUE SE FOSSE A PULVERIZAÇÃO SUSPENSA ANTES DO ESCORRIMENTO

O AGRUPAMENTO DE GOTAS IMPEDE A PENETRAÇÃO NA MASSA FOLIAR

FAZENDO COM FIQUEM NAS FOLHAS EXTERNAS, ESCORRAM ATINGINDO O SOLO

*

PARA TERMOS EFICIENCIA, NECESSITAMOS DE

COBERTURA MÁXIMA DA ÁREA FOLIAR

PARA TERMOS BOA COBERTURA, PRECISAMOS

AUMENTAR O NÚMERO DE GOTAS

PARA AUMENTAR O NÚMERO DE GOTAS,PRECISAMOS

REDUZIR SEU TAMANHO

*

PULVERIZAÇÃO ELETROSTÁTICA,NÃO DEIXA GOTAS SE AGRUPAREM NO TRAJETO ATÉ A FOLHA, POIS

POSSUEM SE REPELEM DEVIDO A MESMA POLARIDADE

O TRAJETO DAS GOTAS É CURVO, DEVIDO À ATRAÇÃO PELAS PLANTAS

GOTAS INFERIORES A 100 MICRA SÃO DEPOSITADAS EM GRANDE NÚMERO POR ESSA FORÇA DE ATRAÇÃO

O QUE É DIFICULTADO QUANDO AS MESMAS NÃO POSSUEM CARGA