7/29/2019 Filtros Quincy
1/12
QUINCY AIR SYSTEMS
FILTERS
COALESCERS
ABSORBERS
ELEMENTS
The Science of Compressed Air
7/29/2019 Filtros Quincy
2/12
C O M P R E S S E D A I R F I LT E R S
STANDARD FILTERS
Particulate Coalescer Absorber
Our Standard Filtration lineup consists of the threemost common types of filters used in compressedair systems.
THE QUINCY DCN SERIES
Particulate/Coarse Coalescer is designed to removesolids, burnt oil and bulk liquids.
THE CSN, CPN, CXN SERIES
Coalescers remove various levels of liquid aerosolsand mist.
THE ACN SERIES
Activated Carbon Absorbers remove vapors andodors.
10 scfm to 16,500 scfm
230 psig max. working pressurefor threaded filters
150 psig max. working pressurefor flanged filters
Aluminum housing (12" to 3" NPT)
Steel housing (3" to 12" FLG)
MOISTURE SEPARATORS
20 to 1500 scfm, 230 psig
Aluminum housing ( 14" to 3" NPT)
OVER & UNDER
COALESCER/ABSORBER
COMBINATION
10 to 50 scfm/230 psig
Two-in-one design
BREATHABLE AIR SYSTEMS
FOR PAINT OR SANDBLAST
APPLICATIONS(Will not remove certain types ofgases, including CO or CO2 )
15 cfm two-port manifold
30 scfm, four-port manifold
230 psig max. working pressure
Floor stand or wallmounting brackets Air pressure regulator
Air pressure gauge
Available air heater
HIGH-TEMPERATURE
DUST FILTER
+450F/150 psig
15 to 1600 scfm
Quincy Filters protect pneumatic equipment and processes from the harmful effectsof contaminated compressed air by removing dirty water, burnt oil and solid pollutants
before they can do any damage. Clean compressed air will result in improved productionand reduced operating costs. World class, state-of-the-art material and design make QuincyCompressed Air Filters the standard to which all others must be compared.
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air2
7/29/2019 Filtros Quincy
3/12
The Science of Air Treatment
ELEMENT CONSTRUCTION
Push-to-Fit Design Aluminum Filters
Easy element replacement
Fit integrity eliminates leaks,saving energy
Stainless Steel Support Core Provides strength
Eliminates corrosion
Protects element from burstingunder high differential pressure
1st Stage Pre-Filtration Support Layer
Captures larger contaminates
Protects 2nd Stage filtration media
Extends service life
Multiwrap 2nd Stage
High void volume minimizespressure drop, saving energy
Increased surface area ensuresmaximum contaminant retention
Extended life construction
Deep bed provides optimumcoalescing efficiency
Selected media combinationsprovide precise filtration solutions
3rd Stage Interceptor Layer
Provides additional strength
Optimizes interception process
4th Stage Outer Stainless Steel Support
Ensures total element integrity
Inside to Out Flow
Prolongs element life andimproves drain performance
Polyester Needle Felt Drainage Layer
Optimum oil removal
High temperature tolerance
Maximum durability
Will not disintegrate Suitable foruse with mineral
and synthetic oils
Tolerant in aggressive environments
Glass-Filled Nylon End Caps
Color-coded for simple elementgrade identification
Easy element replacement
Will not corrode
Quincys Layered Multiwrap design employs a specially blended borosilicate glassmicrofiber media to produce strong, durable and efficient filter elements. The filtrationmedia combines high flow rates and high dirt-holding capacities without compromising
element service life. Easy to identify and easy to install, these highly advanced productsoffer the best performance available
ELEMENTS
7/29/2019 Filtros Quincy
4/12
C O M P R E S S E D A I R F I LT E R S
STANDARD LINE PARTICULATE COALESCER ABSORBER
Quincys Standard Filtration lineup consists of the three most common types of filters used
in compressed air systems. Aluminum housings with threaded NPT connections are usedfor flows up to 1530 cfm and steel housings with flanged connections are used for flowsup to 16,500 cfm.
Push-to-fit designused on threaded filters for easy
filter element replacement
Multiwrap element construction ensures optimum
performance
Modular design saves energy and allows for easy
installation of multiple threaded filters
Aluminum housings feature electrophoretic coating
to prevent corrosion 10-year housing guarantee on aluminum housings
Standard pressure differential indicator
Standard automatic condensate drain
STEEL HOUSINGS,
FLANGED CONNECTIONS 1500 TO 16,000 CFM
SERIES DCNF, CSNF, CPNF, CXNF AND ACNF
DCNT SERIES
Designed to remove highconcentrations of solids,burnt oil and bulk liqu id s
DCNT 5 micron, 5 ppm
CSNT, CPNT, CXNT SERIES
Designed to coalesce variouslevels of liqu id aerosols. The1 micron CSN is also an ideal
afterfilter for desiccant dryers.
CSNT 1 micron, 0.1 ppm
CPNT .01 micron, .01 ppm
CXNT .01 micron, .001 ppm
ACNT SERIES
Activated Carbon Absorberdesigned to remove vaporsand odors. Installed imme-
diately downstream ofeither a CPNT or a CXNTcoalescer, itwill reduceoil carryoverto .003 ppm.
Same filtration grade as aluminum filters
Identified with an F suffix
U stamped for the USA and CRN approved for Canada
Housings are freestanding and top loading for easy element replacement
All grades of filter element end caps are molded, providing strength,
durability and long life
ALUMINUM HOUSINGS,
THREADED CONNECTIONS 10 TO 1530 CFM
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air4
7/29/2019 Filtros Quincy
5/12
The Science of Compressed Air
Grade 10 14 10 17 Grade E 10 1 3 112 8 3 1.43 0.65 72 35 210 75Grade 20 14 20 33 Grade E 20 1 3 112 8 3 1.43 0.65 72 35 210 75Grade 30 38 30 50 Grade E 30 1 3 112 8 3 1.43 0.65 72 35 210 75Grade 60 12 60 100 Grade E 60 1 312 114 13 4 2.87 1.30 88 32 315 100Grade 125 34 125 208 Grade E 125 1 5 112 15 4 5.95 2.70 125 39 365 100Grade 150 1 150 250 Grade E 150 1 5 112 15 4 5.95 2.70 125 39 365 100Grade 200 1 200 333 Grade E 200 1 5 112 21 6 7.72 3.50 125 39 515 150Grade 300 114 300 500 Grade E 300 1 5 112 21 6 7.72 3.50 125 39 515 150Grade 425 112 425 708 Grade E 425 1 512 2 22 6 9.70 4.40 135 50 545 150Grade 500 2 500 833 Grade E 500 1 512 2 22 6 9.70 4.40 135 50 545 150Grade 650 2 650 1083 Grade E 650 1 512 2 30 6 11.00 5.00 135 50 745 150Grade 800 212 800 1333 Grade E 800 1 8 2 34 32 8 25.40 11.50 200 68 805 200Grade 1000 3 1000 1667 Grade E 1000 1 8 2 34 32 8 25.40 11.50 200 68 805 200Grade 1300 3 1300 2167 Grade E 1300 1 8 2 34 37 8 34.20 15.50 200 68 925 200Grade 1525 3 1525 2542 Grade E 1525 1 9 212 42 12 41.90 19.00 230 65 1050 300
STANDARD LINE SPECIFICATIONS & ENGINEERING DATA
MetricElement Number Dimensions DimensionsFilter Model Pipe Size Flow Rate Model of A B C D Weight A B C D(Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Complete Filter Assemblies
Grade 1503 3 1500 2550 Grade 1500 1 58 15 48 10 165 74 1472 381 1219 254Grade 1504 4 1500 2550 Grade 1500 1 58 1718 48 612 175 80 1473 435 1219 165Grade 2004 4 2000 3400 Grade 2000 1 58 2138 4814 13 320 145 1473 543 1226 330Grade 2006 6 2000 3400 Grade 2000 1 5914 2512 48 712 360 163 1505 648 1219 191Grade 3004 4 3000 5100 Grade 3000 1 72 2138 6214 13 385 175 1829 543 1581 330Grade 3006 6 3000 5100 Grade 3000 1 7514 25.5 64 712 420 191 1911 648 1626 191Grade 4506 6 4500 7650 Grade 1500 3 8312 2514 6812 2312 580 263 2121 641 1740 597Grade 6008 8 6000 10200 Grade 1500 4 8634 25 68 23 650 295 2203 635 1727 584Grade 10510 10 10500 17850 Grade 1500 7 100 31 80 30 800 363 2540 787 2032 762Grade 16512 12 16500 28050 Grade 1500 11 11334 4412 87 16 1000 454 2889 1130 2210 406
MetricElement Number Dimensions Dimensions
Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D(Grade) Flg. scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
DCNE 3 4 5 5.0 5.0 248 120 1 40 1 75 6 400 232 16 GreenCSNE 2 2 1 0.1 0.1 248 120 1 75 2 150 6 400 232 16 RedCPNE 1 1 0.01 0.01 0.01 248 120 2 100 4 300 6 400 232 16 BlueCXNE 1 1 0.01 0.001 0.001 248 120 2 140 5 350 6 400 232 16 BlackACNE 1 1 0.01 0.003 0.003 77 25 1 75 Min.every 6 months 232 16 Black
Max. Pressure Loss Max. ElementMax. Particle Oil Carryover Max. Change Working End Cap
Filter Max. Particle Size Oil Content Class Removal at 68F at 20C Temperature Clean & Dry Wet Element Pressure ColorElement to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns ppm mg/m3 F C psi mbar psi mbar psi mbar psig barg Code
Specs
Steel Housings Flanged
Operating psig 4 9 15 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232Pressure barg 0.3 0.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51
For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.
Correction Factor
Model Grades 10, 20 & 30 Model Grades 601525
Model Grades 1503, 1504& 2004
Model Grades 200616512
A
C
D
A
C
B
B
D
7/29/2019 Filtros Quincy
6/12
C O M P R E S S E D A I R F I LT E R S
HIGH TEMPERATURE 1 MICRON DUST FILTERS, 450F, 150 PSIG
Features a high-temperature dust filter
with heavy-duty bowl
Ribbed bowl facilitates removal when
changing elements
NOTE: Alloy filters shipped loose will have a special
high-temperature black powder coat paint.
Nomex outer layer is provided for high-temperature operation
Push-to-fit designused on threaded filters for easy filter element replacement
Multiwrap element construction provides optimum performance
ALUMINUM HOUSINGS,
THREADED NPT CONNECTIONS
15 TO 650 CFM,
SERIES HTDT
Same filtration grade as aluminum filters
Identified with an F suffix
U stamped for the USA and CRN approvedfor Canada
Differential pressure indicators are standard
Housings are freestanding and top-loading
for easy element replacement
All grades of filter element end caps are
molded, providing strength, durability
and long life
STEEL HOUSINGS,
FLANGED CONNECTIONS
1500 TO 16,000 CFM,
SERIES HTDF
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air6
7/29/2019 Filtros Quincy
7/12
The Science of Compressed Air
HTDT 15 14 15 25 HTDE 15 1 212 12 6 2 0.5 0.25 63 15 150 50HTDT 30 38 30 50 HTDE 30 1 212 12 712 2 0.6 0.27 63 15 190 50HTDT 65 12 65 108 HTDE 65 1 412 112 12 6 5.7 2.60 114 38 305 150HTDT 75 34 75 125 HTDE 75 1 412 112 12 6 5.7 2.60 114 38 305 150HTDT 150 1 150 250 HTDE 150 1 412 112 1512 6 7.3 3.30 114 38 395 150HTDT 300 112 300 500 HTDE 300 1 534 2 21 7 16.5 7.50 146 50 435 170HTDT 450 2 450 750 HTDE 450 1 534 2 21 7 16.5 7.50 146 50 435 170HTDT 650 2 650 1084 HTDE 650 1 534 2 25 7 22.0 10.00 146 50 635 170
HIGH TEMPERATURE SPECIFICATIONS & ENGINEERING DATA
MetricElement Number Dimensions DimensionsFilter Pipe Size Flow Rate Model of A B C D Weight A B C DModel NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Dust Filters Threaded
HTDF 1503 3 1500 2550 HTDE 1500 1 58 15 48 10 165 74 1473 381 1219 254HTDF 1504 4 1500 2550 HTDE 1500 1 58 1718 48 612 175 80 1473 435 1219 165HTDF 2004 4 2000 3400 HTDE 2000 1 58 2138 4814 13 320 145 1473 543 1226 330HTDF 2006 6 2000 3400 HTDE 2000 1 5914 25.5 48 712 360 163 1505 648 1219 191HTDF 3004 4 3000 5100 HTDE 3000 1 72 2138 6214 13 385 175 1829 543 1581 330HTDF 3006 6 3000 5100 HTDE 3000 1 7514 2512 64 712 420 191 1911 648 1626 191HTDF 4506 6 4500 7650 HTDE 1500 3 8312 2514 6812 2312 580 263 2121 641 1740 597HTDF 6008 8 6000 10200 HTDE 1500 4 8634 25 68 23 650 295 2203 635 1727 584HTDF 10510 10 10500 17850 HTDE 1500 7 100 31 80 30 800 363 2540 787 2032 762HTDF 16512 12 16500 28050 HTDE 1500 11 11334 4412 87 16 1000 454 2889 1130 2210 406
MetricElement Number Dimensions Dimensions
Filter Pipe Size Flow Rate Model of A B C D Weight A B C DModel Flg. scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Dust Filters Flanged
High-temperature dust filter element gradeHTDE 1 2 2 450 250 1.1 75 NA NA 6 400 150 10 Brick Red
Max. Pressure Loss Max. ElementParticle Oil Carryover Max. Change Working End Cap
Filter Removal at 68F at 20C Temperature Clean & Dry Wet Element Pressure Color
Element in Microns ppm mg/m3 F C psi mbar psi mbar psi mbar psig barg Code
Specs
ModelsHTDT 15 & 30
ModelsHTDT 65650
Operating psig 145 290 435 580 725Pressure barg 10 20 30 40 50Correction Factor 0.34 0.57 0.71 0.86 1.0
For maximum flow rate, multiply model flow rateshown in the above table by the correction factorcorresponding to the working pressure.
Correction Factor
ModelsHTDF 1503, 1504 and 2004
Models HTDF 200616512
A
C
D
A
C
B
B
D
7/29/2019 Filtros Quincy
8/12
BREATHABLE AIR SYSTEMS
15 TO 30 CFM
Quincy Breathable Air Packages are completesystems designed to provide, clean, odor-free,taste-free, particle and liquid oil-free compressed
air for sand blasting and/or painting hoods. The15-cfm system has two outlet ports and can
accommodate two suits. The 30-cfm packagehas four outlet ports and can accommodate four
suits. The system provides absolute filtrationdown to 0.01 micron and oil removal down to0.003 ppm. Special non-shedding, high-speed
carbon granules increase vapor-holding capacity.
The System Includes:
Aluminum housings with electrophoretic
coating to prevent corrosion
WSNT moisture separator
CSNT 1 micron, 0.1 ppm Coalescer
QUDT with CPNT 0.01 micron, 0.01 ppm
and .003 ppm activated carbon absorber
Wallmounting or floor-mounting
configuration
The System includes:
Combination Coalescer and Activated Carbon Absorber
Two functions in one unit
Space-saving Over & Under configuration
Push-to-fit design for easy filter element replacement
Multiwrap element construction ensures
optimum performance
Non-shedding, high-speed carbon granules
increase vapor-holding capacity
Aluminum housings with electrophoretic
coating to prevent corrosion.
Standard pressure differential indicator
Standard automatic condensate drain
Using a unique two-sided head, Quincys Over & Under Duplex filtercombines a CPN Series (0.01-micron, 0.01-ppm) coalescer with an
ACN Series (.003-ppm) activated carbon absorber. This compact, two-stage, single-piece filtration system saves space, is easy to install and
delivers ISO 8573.1 class 1 compressed air. The Over & Under is idealfor food and beverage, instrumentation and pharmaceutical applications.
OVER & UNDER DUPLEX
10 TO 50 CFM, SERIES OUDT
C O M P R E S S E D A I R F I LT E R S
Push-to-fit design
PNF drain layer
Pressure differential
indicator
Multiwrap construction
Air pressure regulator
and gauge
Activated carbon element impregnated
with red dye oil indicator
Color-coded end caps
Compressed air heater option
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air8
7/29/2019 Filtros Quincy
9/12
The Science of Compressed Air
WARNING: The Breathable air systems described in this brochurewill not remove certain types of gases, including Carbon Mon-oxide (CO) and Carbon Dioxide (CO2). These Breathable AirSystems are designed to offer the user protection in potentiallyharmful environments. It is therefore imperative the products be
correctly installed and properly controlled by a competent person.Properly controlled means the equipment installed should befully checked prior to every use. Should any fault be discovered,it must be repaired or the failed component replaced to guaran-tee full working order before use.
Wallmounted Breathable Air PackagesBWST 15 14 2 15 25 BAEK 15 1 Kit 1014 1234 1234 3 0.50 0.25 280 360 323 77BWHT 15 14 2 15 25 BAEK 15 1 Kit 1534 18 1314 4 0.60 0.27 418 498 337 100BWST 30 38 2 15 25 BAEK 30 1 Kit 1014 1234 1234 3 5.70 2.60 280 360 323 77BWHT 30 38 2 15 25 BAEK 30 1 Kit 1534 18 1314 4 5.70 2.60 418 498 337 100
Frame-Mounted Breathable Air PackagesBFST 15 14 4 30 50 BAEK 15 1 Kit 1934 NA 1734 1934 2.35 1.05 500 NA 450 500BFHT 15 14 4 30 50 BAEK 15 1 Kit 1934 NA 1734 1934 2.35 1.05 500 NA 450 500BFST 30 38 4 30 50 BAEK 30 1 Kit 1934 NA 1734 1934 2.35 1.05 500 NA 450 500BFHT 30 38 4 30 50 BAEK 30 1 Kit 1934 NA 1734 1934 2.35 1.05 500 NA 450 500
MetricPipe Air Element Number Dimensions Dimensions
Filter Size Outlet Flow Rate Model of A B C D Weight A B C DModel NPT Ports scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Breathable Air Packages
Operating psig 4 9 15 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232Pressure barg 0.3 0.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1.0 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51
For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.
Correction Factor
Breathable Air Package KitBAEK 1 1 >0.01 >0.003 >0.003 77 25 3.7 250 6.6 950 Min.every 6 months 145 10 Red/Blue/Black
Duplex Filter Kit (OUDK)CPNE 1 1 0.01 0.01 0.01 248 120 2.2 150 4.4 300 6 400 232 16 BlueACDE 1 1 0.01 0.003 0.003 77 25 1.1 75 NA NA Min.every 6 months 232 16 Black
Max. Pressure Loss Max. ElementMax. Particle Oil Carryover Max. Change Working End Cap
Filter Max. Particle Size Oil Content Class Removal at 68F at 20C Temperature Clean & Dry Wet Element Pressure ColorElement to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns ppm mg/m3 F C psi mbar psi mbar psi mbar psig barg Code
Specs
OUDT 10 14 10 17 OUDK 10 1 Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT 15 14 15 25 OUDK 15 1 Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT 30 38 30 50 OUDK 30 1 Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT 50 12 50 83 OUDK 50 1 Kit 312 8 9 4 2.75 1.25 90 200 225 100
MetricElement Number Dimensions Dimensions
Filter Pipe Size Flow Rate Model of A B C D Weight A B C D
Model NPT scfm Nm3
/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm
Over & Under Duplex
ModelsBWST 15 & 30
ModelsBFST 15 & 30
ModelsOUDT 1050
BREATHABLE AIR, OVER & UNDER DUPLEX SPECIFICATIONS & ENGINEERING DATA
7/29/2019 Filtros Quincy
10/12
C O M P R E S S E D A I R F I LT E R S
MECHANICAL MOISTURE SEPARATORS
20 TO 1500 CFM, 230 PSIG, SERIES WSNT
Quincy Mechanical Moisture Separators are designed to remove bulk liquids andlarge volumes of water. They are typically installed downstream of aftercoolers, air
receivers, refrigerated air dryers and at strategic points of use throughoutthe compressed air distribution system. The design employs an
internal spinner to create a centrifugal action that effectivelyremoves large quantities of water.
Large sump and quiet zone to prevent moisture
re-entrainment
Modular design allows for easy installation
of multiple housings and saves energy
Annular seal and captive Oring prevent leaks
Aluminum housings (14" to 3 NPT) feature
electrophoretic coating to prevent corrosion
Aluminum housings (14" to 3" NPT) carry
a 10-year housing guarantee
Standard automatic condensate drain
WSNT 20 14 20 35 3 114 814 3 1.45 0.65 72 35 210 75WSNT 30 38 30 50 3 114 814 3 1.45 0.65 72 35 210 75WSNT 63 12 63 112 312 114 814 4 2.90 1.30 88 32 210 100WSNT 127 34 127 216 5 112 12 4 5.95 2.70 125 39 300 100WSNT 176 1 176 300 5 112 12 4 5.95 2.70 125 39 300 100WSNT 318 114 318 540 5 112 12 4 5.95 2.70 125 39 300 100WSNT 427 112 427 725 512 2 19 6 9.70 4.40 135 50 480 150WSNT 675 2 675 1150 512 2 19 6 9.70 4.40 135 50 480 150WSNT 1000 212 1000 1700 8 234 24 8 25.5 11.5 200 68 590 200WSNT 1500 3 1500 2550 8 234 24 8 25.5 11.5 200 68 590 200
MetricDimensions Dimensions
Filter Pipe Size Flow Rate A B C D Weight A B C DModel NPT scfm Nm3/hr In. In. In. In. lb. kg. mm mm mm mm
Moisture Separators
Operating psig 4 9 15 29 44 58 72 87 100Pressure barg 0.3 0.6 1 2 3 4 5 6 7Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1
Operating psig 115 130 145 160 174 189 203 218 232Pressure barg 8 9 10 11 12 13 14 15 16Correction Factor 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51
For maximum flow rate, multiply model flow rate shown in the above table by thecorrection factor corresponding to the working pressure.
Correction Factor
WSNT 248 120 35 1.5 0.7 50 232 16
Max. Min. Typical Max.Recommended Recommended Pressure Loss Working
Filter Operating Temp. Operating Temp. At Rated Flow PressureModel F C F C psi mbar psig barg
Specs
SPECIFICATIONS & ENGINEERING DATA
QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air10
7/29/2019 Filtros Quincy
11/12
The Science of Compressed Air
QUINCY SYSTEM PRESSURE TRANSMITTERS
Quincy System Pressure Transmitters sense pressure, differential pressure or both
at specific points throughout a compressed air system. Accurate to half of 1%,a 4 to 20 mA signal continuously transmits readings to the systems main
control station.
Continuous and accurate pressure tracking facilitates periodic
compressed air audits and enables the automation and/or operatorto monitor the system and adjust controls for optimum efficiency.
Reduce energy and filtration costs
Improve air treatment efficiency
Monitor critical applications
24/7 operation
Simple and cost-effective installation
Guaranteed for 5 years
Rugged NEMA 4/IP65 rating
ACCESSORIES
Quincy filtration products come standard with mechanicalcondensate drains and are available with
Optional electronic timer drains
Optional pneumatic no-loss drains
Optional electronic no-loss drains
Quincy Filters are equipped standard with top-mounted pressure indicators.
Pop-up for 10 cfm through 30 cfm
( 12" NPT & 3/8" NPT)
Gauge for 50 cfm through 16,500 cfm
( 12" NPT through 12" FLG)
Multiple filters can be ganged together using the available two- and three-unit
connecting kits.
Eliminates leaks, saving energy
Easy and space-saving installation
Aluminum Alloy filters can be wallmounted using the available wallmounting brackets.
Provides easy and flexible installation
1
7/29/2019 Filtros Quincy
12/12
quincycompress or.com
QGV-100quincycompressor.com
QPNC-500quincycompressor.com
QDHT-1000quincycompressor.com
Air Quality ClassificationISO 8573.1
Quincy Rotary Screw WSNBulk
LiquidDP1
WetReceiver
1gal/CFMDP2
DryReceiver
5gal/CFM
CSN1 Micron0.1 PPM
DP3
CPN0.01 Micron
0.01 PPMDP5
ACN0.003 PPMVapor &
Odors
Solids
Micron ISO PDP ISO PPM ISO
0.01 1 +38F 4 0.01 1 10.7 738
0.01 1 +38F 4 0.003 1 11.8 814
1 2 -40F 2 0.01 1 9.2 634
0.01 1 -40F 2 0.003 1 10.3 710
1 2 +50F 6 0.01 2 7.8 538
0.01 1 +50F 6 0.003 1 10.0 689
1 2 -40F 2 0.01 1 9.2 634
0.01 1 -100F 1 0.001 1 14.2 979
Moisture Oil
psi Mbar
Refrigerated Air DryerQPNC Non-Cycling
QPCD CyclingDP4
WetSystemAvg. P
Quincy Reciprocating AC
WSN Moisture Separator
DCN Particulate/Coarse Coalescer
CSN STD 0.1 PPM Coalescer, 1 Micron
CPN Polishing 0.01 PPM Coalescer
CXN Xtra 0.001 PPM Coalescer
ACN Activated Carbon Absorber
OUD Over + Under Duplex
HTD High Temperature,1 Micron
QPNC Non-Cycling Refrigerated Dryer
QPCD Cycling Refrigerated Dryer
QDTS Small Heatless Dryer
QDTH Industrial Heatless Dryer
QDHP Heated Purge Dryer
QDBP Blower Purge Dryer
QPHT High Temp. Refrigerated Dryer
WOS Water/Oil Separator
AC After Cooler
DP Drain Point
WSNBulk
LiquidDP6
DryReceiver
5gal/CFM
CPN0.01 Micron0.01 PPM
DP7
CSN (NPT)HTD (FLG)1 Micron
Particulate
ACN0.003 PPMVapor &
Odors
0.01 1 -40F 2 0.003 1 10.3 710
ACN0.003 PPMVapor &
Odors
Desiccant Heatless Air DryerQDTSSmall
QDTHIndustrial-40F PDP
DCN5 Micron
5 PPMDP9
WOSWater/OilSeparator
CSN1 Micron0.1 PPM
DP11 CPN0.01 Micron
0.01 PPM
ACN0.003Micron
OUD
High Temperature/Refrigerated Air DryerQPHTHigh Temp.
DP10
DryReceiver
5gal/CFM
CPN0.01 Micron0.01 PPM
DP8
Desiccant Heated Air DryerQDHPHeated PurgeQDBPBlower Purge
-40F PDP
QDHP-1000quincycompressor.com
Approximate Liquid Removal100 CFM, 100 psi, 80F, 4000 hrs./yr., 2 PPM
DrainPoint
1234
30002000305
1300
Gallonsper Year
DrainPoint
5678
1403000310310
Gallonsper Year
DrainPoint
91011
3004320120
Gallonsper Year
QPHT-40quincycompressor.com
NOTE: Requires CXN (.001 PPM) filter in
series with standard CPN prefilter.
CSN1 Micron
Particulate
701 North Dobson Avenue | Bay Minette, AL 36507 | Phone 251.937.5900 | Fax 251.937.7182 | Nearest Distributor: 888.424.7729 | Email: [email protected]
2005 Quincy Compressor anEnPro IndustriescompanyAll rights reserved. Litho in U.S.A. (QATF-001 03/05)
The Science of Compressed Air
COMPRESSED AIR SYSTEMS BEST PRACTICE