NT 65/2 Eco *VEX
2
Lists of contents EN PageCommissioning 3Operating Instructions 4Kärcher branches 19Technical Data / Wiring diagram / Spare Parts List 20/21/22Accessories / Filter systems 23/25
Prior to initial startup, operating manual and safety instructionsno. 5.956-249 must be consulted! This machine is suitable for industrial use, forinstance in hotels, schools, hospitals, factories, shops, offices and on hire.
Índices ES PaginaciónPuesta en servicio 3Instrucciones de servicio 9Filiales de Kärcher 19Datos técnicos / Diagrama de conexiones / Lista de piezas de requesto 20/21/22Accesorios / Sistemas de filtros 23/25
Las instrucciones de servicio y las indicaciones de seguridad núm. 5.956-249 sedeben leer imprescindiblemente antes de la primera puesta en servicio!Este aparato es apropiado para el uso a escala industrial, p. ej. en hoteles, centrosescolares, hospitales, fábricas, tiendas comerciales, oficinas y empresas dedicadas alalquiler.
Tables des matières FR PageMise en service 3Notice d'instructions 14Filiales Kärcher 19Caractéristiques techniques / Schéma de câblage /Liste des pièces de rechange 20/21/22Accessoires / Systèmes de filtres 23/25
Avant la première mise en service, lire absolument le mode d’emploi et les. 5.956-249remarques de sécurité! Cet appareil est adapté à l'usage professionnel, p. ex. dans leshôtels, les écoles, les hôpitaux, les usines, les magasins, les bureaux et les locations.
Operating instructions NT 65/2 Eco *VEX English
4
Important
Prior to initial operation of the unitwe request you to carefully readthe information given in theoperating instructions.
Inform your dealer immediatelyof shipping damage.
Environmental protectionItems used when working, such asfuel, oil, cleaning agent andcontaminated maintenancematerials, are to be deposited at aspecial collection point.
Packaging materials, metal andplastic containers are to be setaside for recycling as appropriate.
Disposal of used unitsYour Kärcher retailer will provideyou with information on disposalmeans harmless to theenvironment.
Intended use— This vacuum cleaner is a
cleaning unit for industrialapplications.
— The unit is designed for wetand dry cleaning of floors andwalls in the home, in businessand industrial premises inaccordance with theseoperating instructions.
— When the unit is used it is notpermissible for the ambienttemperature to exceed 40°C.
Dry suction
Warning!During vacuuming it is notpermitted to ever remove the flatpleated filter.
A paper filter bag or a diaphragmfilter (special accessories) canadditionally be used to vacuumfine dust.
Fitting the paper filter bag
! Unlock and remove the suctionhead
! Attach the paper filter bag
Operating instructions NT 65/2 Eco *VEX English
5
! Replace the suction head andlock it in place
! Insert power plug! Switch on the machine and
start using it
Filter de-duster
Power Filter Clean
Your vacuum cleaner is providedwith a new type of filter cleaner –especially effective for fine dust.
The flat pleated filter isautomatically cleaned by an airblast if you press the push buttonat the handle for approx. 5 to10 seconds (pulsating sound)Prior to that the Power Filter Cleanmust be activated.
To activate Power Filter CleanSlider (1) position - down
Note:Actuating the push button at thehandle every 5 to 10 minutesincreases the filter service life.
To deactivate Power Filter CleanSlider (1) position - up.
Note:For vacuuming with the upholsteryor crevice nozzle or forpredominantly sucking up water.
Operating instructions NT 65/2 Eco *VEX English
6
Wet-vacuuming
! Remove the paper filter bag
! Insert power plug! To deactivate Power Filter
Clean! Switch on the machine and
start using it
To deactivate Power Filter CleanSlider (1) position - up.
Note:— It is advisable to deactivate the
- Power Filter Clean - functionwhen vacuuming with theupholstery or crevice nozzle orif predominantly water is to besucked out of a container.
Upon reaching the maximum liquidlevel the unit automatically turnsitself off.
! Switch the appliance off andempty the container.
Automatic shutoff is reset byturning off the unit.
! Clean and dry the flat pleatfilter and the electrodes as wellas the container after finishingwet vacuuming jobs.
! Drain dirty water using thedrain (not provided for all units)
Warning!— During vacuuming it is not
permitted to ever remove theflat pleated filter.
— The paper filter bag and themembrane filter (optionalaccessories) respectively mustalways be removed forvacuuming wet dirt. The use ofa special filter bag (wet type) isrecommended(see filter systems).
— The unit does not switch offwhen the container is full whennon-conductive liquids (e.g.drilling emulsion, oils andgreases) are vacuumed. The filllevel must be regularly checkedand the container emptiedbefore it is too full.
— On request, the unit can beretrofitted by maintenanceservice with a shutoff fordielectric liquids.
Operating instructions NT 65/2 Eco *VEX English
7
Care and maintenance
Danger!Always pull out the mains plugwhen working on the suctionmachine.
Replacing the flat pleated filteror the exhaust air filter
! Open the filter cover (1)! Replace the flat pleated
filter (2) or the exhaust airfilter (3)
! Close the filter cover, it mustengage audibly
Clean electrodes
! Unlock and remove the suctionhead
! Clean electrodes! Replace the suction head and
lock it in place
Fault instructions
The suction turbine does notrun! Check the cable, plug, fuse and
socket.! Switch on the machine.
The suction turbine switches off! Empty the container.
The suction turbine does notrestart following emptying ofthe container! Switch the appliance off and
wait for 5 s, switch it on againafter 5 s.
! Clean the electrodes as well asthe space between them.
The suction power decreases! Remove the parts clogging up
the suction nozzle, the suctiontube, the Power Filter Cleanhandle, the suction hose or theflat pleat filter.
! Change the paper filter bag.! Actuate the filter
cleaner: Power Filter Cleanseveral times at the handle.
! Engage the filter coverproperly.
! Replace the flat pleat filter.! Check drain hose for leaks
(if provided).
Dust ejects when sucking! Check the proper mounting
position of the flat pleat filter.! Replace the flat pleat filter.
The (wet-vacuuming) automaticswitch-off does not respond! Clean the electrodes as well as
the space between them.! Constantly check fill level when
vacuuming electrically non-conductive liquids.
Power Filter Clean switchesregularly! Detach blocked suction nozzle
or end of hose.! Stop continuous vacuuming
from liquid tank or deactivatethe Power Filter Clean function(see chapter on wet-vacuuming).
! Remove the parts clogging upthe suction nozzle, the suctiontube, the Power Filter Cleanhandle, the suction hose or theflat pleat filter.
! Replace the flat pleat filter.
Operating instructions NT 65/2 Eco *VEX English
8
EC conformitydeclarationWe hereby declare that themachine specified belowas the marketed desigh, themachine specified belowcomplies with the relevantfundamental safety and healthrequirements of the EC directiveslisted below.Modification of the machinewithout our approval invalidatesthis declaration.
Product: Wet and dry vacuumcleanerType: 1.325-xxx
Relevant EC directivesEC machine directive (98/37/EC)EC low voltage directive(73/23/EEC) amended by93/68/EECEC directive on electromagneticcompatability (89/336/EEC)amended by 91/263/EEC,92/31/EEC, 93/68/EEC
Applied harmonised standardsDIN EN 60335-1DIN EN 60335-2-69DIN EN 55014-1:2000 + A1:2001DIN EN 55014-2:1997DIN EN 61000-3-2:2000DIN EN 61000-3-3:1995 +A1:2001
Applied national standards-
Internal measures ensure that thein series produced units alwayscomply with the requirements ofcurrent EC directives and appliedstandards. The signatories act forand in authority of management.
5.957-701 (05/02)
Alfred Kärcher LimitedPartnership.Registered office: Winnenden.Company Register: Waiblingen,HRA 169.Personally liable partner. KärcherReinigungstechnik GmbH.Registered office Winnenden,2404 Waiblingen CompanyRegister, HRB
Managing directors:Dr. Bernhard Graf,Hartmut Jenner, Georg Metz
Alfred Kärcher GmbH & Co. KGCleaning SystemsAlfred-Kärcher-Strasse 28-40P.O.Box 160D-71349 WinnendenPhone: ++49 7195 14-0Fax :++49 7195 14-2212
NT 65/2 Eco *VEX
19
ATAlfred Kärcher Ges. m.b.H.Lichtblaustraße 7A-1220 Wien
AUKärcher (Pty.) Ltd.2/158 Browns RoadNoble Park 3174Melbourne, Vict.
BE, LU, NLKärcher BeneluxIndustrieweg 122320 Hoogstraden
BRKärcher Industria e Comércio Ltda.Av. Prof. Benedicto Montenegro
n°419Paulinia – Estado de Sao PauloCEP 13.140-000
CAKärcher Cleaning Systems Inc.1770 Alstep DriveMississauga, Ontario L5S1W1
CHKärcher Variorapid AGIndustriestr. 16CH - 8101 Dällikon
CZKärcher spol. S. r. a.Za Mototschnou155 00 Praha – Stodůlky
DEAlfred Kärcher GmbH & CoVertrieb DeutschlandFriedrich - List - Straße 4D - 71364 Winnenden
DKKärcher A/SGejihavegaard 5DK – 6000 Kolding
ESKärcher S.A.Pol. Industrial Font del RadiumCalle Doctor Trueta 6-7E - 08400 Granollers (Barcelona)
FRKärcher S.A.Z.A. des Petits Carreaux5, avenue des CoquelicotsF - 94865 Bonneuil s. Marne/CEDEX
FIKärcher OyYrittäjäntie 17FIN - 01800 Klaukkala
GBKärcher (U.K.) Ltd.Kärcher HouseBeaumont RoadBanbury Oxon, OX 16 7TB
GRKärcher S.A.Cleaning Systems99 Aristoutelous & IoanninonGR - 136 71 Aharnes
HUKärcher Hungaria Kft.H-2051 Biatorbagy (Vendelpark)Tormasret ut 2
HKKärcher Ltd.Unit 10, 17/FL. APEC Piaza49 Hoi Yuen RoadKwun Tong, Kowloon
ITKärcher S.p.A.Via Elvetia 4I - 25050 Cantello (VA)
JPKärcher (Japan) Co., Ltd.Irene Kärcher BuildingNo. 2, Matsusaka-Daira 3-chomeTaiwa-cho, Kurokawa-gunMiyagi, 981-34, Japan
NOKärcher A/SGjerdrumsvei 4Postboks 94, GrefsenN - 0409 Oslo
PTNeopartsComercio e Indústria Autómovel, LdaLargo Vitorino Damásio. 101200 Lisabon
PLKärcher Poland Ltd.Sp. zo. o.Ul. Godlewskiego 2230-198 Kraków
SEKärcher ABBox 24S - 42502 Hisings - Kärra
USAAlfred Kärcher Inc.P.O. Box 65101600 Cottontail LaneSomerset, NJ 08875
ZAKärcher (Pty.) Ltd.P.O. Box 2417Kempton Park 1620
NT 65/2 Eco *VEX
20
120 V AC 60 Hz
10,0 m
SSTW-A 14/3 AWG 6.648-919
74 dB (A)
I: 18 A
65 l
50 l
max. 2 x 54 l/s
max. 235 mbar
Umgebungs- max. 40 °CtemperaturAmbient temperatureTempérature ambiante
600 mm x 480 mm x 920 mm
ohne Zubehör 19 kgwithout accessoriessans accessoires
40 mm
NT 65/2 Eco *VEX
21
B1 ElektrodenElectrodesInterrupteuravancement
C1 KondensatorCapacitorCondensateur
K1 RelaisRelayRelais
K2 RelaisRelayRelais
K3 RelaisRelayRelais
M1 SaugturbineSuction turbineTurbine d’aspiration
M2 SaugturbineSuction turbineTurbine d’aspiration
N1 ElektronikCircuit boardPlatine
S1 NetzschalterMaster switchCommutateur principal
T1 TransformatorTransformerTransformateur
X1 NetzsteckerPlugFiche
X2 VerteilerDistributorDistributeur