2
Braile Biomédica Indústria, Comércio e Representações Ltda. Av. Pres. Juscelino K. de Oliveira, 1505 • Jardim Tarraf I Zipe Code 15091-450 • São José do Rio Preto • SP • Brazil Phone #55 17 2136 7000 • Fax #55 17 2136 7040 Federal Tax ID: 52.828.936/0001-09 Technician in charge: Vladimir D. A. Ramirez • CRF/SP 9010 ANVISA Reg. nº 10159030095 www.braile.com.br INOVARE ® BIOLOGICAL VALVE PROSTHESIS Gala DF, Breda JR, Ferreira CBND, Souza JAM, Buffolo E, Palma JH. Inter J Cardiol. 2013;164:e32-4. Gaia DF, Palma JH, Souza JAM, Ferreira CBND, Macedo MT, Gimenes MV, Buffolo E. Inter J Cardiol. 2012;154:e6-7. Gaia DF, Palma JH, Ferreira CBND, Souza JAM, Gimenes MV, Macedo MT et al. Rev Bras Cir Cardiovasc. 2011;26(3):338-47. Vaijyanath P et al. Indian J Thorac Cardiovasc Surg. 2011;27(2):99-102. Gaia DF, Palma JH, Ferreira CBND, Souza JAM, Agreli G, Guilhen JCS et al. Rev Bras Cir Cardiovasc. 2010; 25(3):293-302. Code Catalog 604510 Rev. 06 Chrome-cobalt metallic frame Bovine Pericardium Radiopaque markers made of tantalum Polyester anti-leak coating

Inovare Valvula Transcateter - Inglês - 604510 · 2021. 6. 23. · Braile Biomédica Indústria, Comércio e Representações Ltda. Av. Pres. Juscelino K. de Oliveira, 1505 • Jardim

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Inovare Valvula Transcateter - Inglês - 604510 · 2021. 6. 23. · Braile Biomédica Indústria, Comércio e Representações Ltda. Av. Pres. Juscelino K. de Oliveira, 1505 • Jardim

Braile Biomédica Indústria, Comércio e Representações Ltda.Av. Pres. Juscelino K. de Oliveira, 1505 • Jardim Tarraf IZipe Code 15091-450 • São José do Rio Preto • SP • BrazilPhone #55 17 2136 7000 • Fax #55 17 2136 7040Federal Tax ID: 52.828.936/0001-09Technician in charge: Vladimir D. A. Ramirez • CRF/SP 9010ANVISA Reg. nº 10159030095www.braile.com.br

INOVARE®

BIOLOGICAL VALVE PROSTHESIS

Gala DF, Breda JR, Ferreira CBND, Souza JAM, Buffolo E, Palma JH. Inter J Cardiol. 2013;164:e32-4.

Gaia DF, Palma JH, Souza JAM, Ferreira CBND, Macedo MT, Gimenes MV, Buffolo E. Inter J Cardiol. 2012;154:e6-7.

Gaia DF, Palma JH, Ferreira CBND, Souza JAM, Gimenes MV, Macedo MT et al. Rev Bras Cir Cardiovasc. 2011;26(3):338-47.

Vaijyanath P et al. Indian J Thorac Cardiovasc Surg. 2011;27(2):99-102.

Gaia DF, Palma JH, Ferreira CBND, Souza JAM, Agreli G, Guilhen JCS et al. Rev Bras Cir Cardiovasc. 2010; 25(3):293-302.

Co

de C

ata

log

60

45

10R

ev.

06

Chrome-cobaltmetallic frame

Bovine Pericardium

Radiopaque markersmade of tantalum

Polyester anti-leak coating

Page 2: Inovare Valvula Transcateter - Inglês - 604510 · 2021. 6. 23. · Braile Biomédica Indústria, Comércio e Representações Ltda. Av. Pres. Juscelino K. de Oliveira, 1505 • Jardim

For a surgical treatment of calcifying aortic stenosis in a native valve.

For treatment of aortic stent-graft dysfunction.

Transapical Access

Transaortic Access| Procedure with ECC

Transaortic Access | Procedure without ECC

Kit comprising

01 Transcatheter valve01 Introducer01 Balloon for Pre-dilatation01 Balloon for Release

Introducer

Introducer

Pre-Dilatation18, 20 mm

Pre-Dilatation18, 20 mm

Release22, 24, 26, 28, 30 mm

Release22, 24, 26, 28, 30 mm

Balloon Catheter

Balloon Catheter

CRIMPERFor a surgical treatment ofcalcifying aortic stenosis in a native valve.

For treatment of dysfunction ofaortic stent-graft.

For a surgical treatmentwhich is minimally invasive,of calcifying aortic stenosis in a native valve.

For valve-in-valve treatment ofaortic stent-graft or dysfunctional mitral

Kit comprising:

01 Transcatheter valve01 Kit of Meters01 Balloon for Pre-dilatation01 Balloon for Release

Kit comprising:

01 Transcatheter valve 01 Introducer01 Balloon for Pre-dilatation01 Balloon for Release

Meters

Pre-Dilatation15 e 18 mm

Release15-18, 22-25 e 27-30 mm

Balloon Catheter

This product is intended for patients

with a high surgical risk for standard

valve change.

20 m

m

20, 22, 24, 26, 28 e 30mm

INOVARE®