    Omniflex Products

    Shortform Catalogue

  • 8/10/2019 Br Products cvFr 03

    2/12

    - 2 - Copyright Omniflex

    OMNIFLEX has been designing and manufacturing electronic products and systems for the automation and control industry since 1965.

    Through our world-wide partner network, we specialise in providing solutions to industry in the fields of Remote I/O, RTUs, Data

    Acquisition, Alarm and Events management, and Process Signal Conditioning Systems. More than 3 decades of experience in

    innovating products and systems such as these have resulted in a refined range of solutions for managing abnormal and critical events

    in Industrial processes. These proven solutions are being relied upon every hour of every day by major corporations round the world.

    Whether its four points or four thousand points, there is an OMNIFLEX solution to your need. Hallmarks of these solutions are reliability,

    flexibility and ease of use, which synergise to become the trusted eyes and ears of many enterprises, peak performing 24 hours a day

    collecting data, analysing logical circumstances and providing the appropriate warnings to personnel and other systems. Building on

    proven technologies, OMNIFLEX continues to research and develop new frontiers to create products that outperform expectations and

    provide true added value. Recognising that productivity, human safety and profitability depend largely on products such as these, reliability

    engineering assumes paramount importance to ensure operation under the most arduous and inhospitable conditions.

    An investment in products that carry such a large responsibility requires confidence in our track record and the continued expansion of

    some of the worlds giant industries using OMNIFLEX technologies, is sufficient testimony to this support. The Omniflex focus over the last

    decade has been to rationalise its product lines into groups to suit our business focus whilst maintaining growth paths for our existing

    customer base world-wide. We actively manufacture product in 3 business areas :

    Alarm and Events Management. Telemetry and Data Acquisition

    I/O Systems

    Alarm and Events Mangement

    This business area comprises :

    Alarm Annunciators

    Sequential Events Recorders and Loggers

    Alarm Management Packages for PC

    Distributed Alarm Annunciation Networked

    Analog Alarm Integration and logging

    Telemetry And Data Acquisition

    This business area comprises:

    RTUs for Data Acquisition

    Multidrop Point to Point Telemetry Systems on cable

    Cable Networking Packet Radio Networking

    Cable Saving Signal Multiplexing

    Plant Wide Data Monitoring

    I/O Systems

    This business area comprises:

    Remote I/O systems

    Signal Conditioning

    Power Supplies

    Loop Isolators Two Wire Transmitters

    Modbus I/O Modules

    Product Overview

  • 8/10/2019 Br Products cvFr 03

    3/12

    - 3 - Copyright Omniflex

    Alarm Annunciators

    This third generation of modular design used on preceding Omni16 ranges has

    been taken to new levels to create even more flexibility with related savings in

    costs by omitting options not required or the ability to add them later. Also

    upgrading from Incandescent lamps to backlit led technology has never been

    easier.

    Available in 8 or 16 Point Modules expandable to 256 Point systems with Modbus

    communications option. DIP switch or PC configurable for maximum flexibility.

    Also on offer is an 8 point micro annunciator in DIN 48x96 Housing and the

    OMNI30, which is a direct replacement for the obsolete RIS UC30 Annunciator.

    The range covers:

    Integral Annunciators Backlit LED, Incandescent, Sidebar LED

    Remote Logic Units

    Remote Displays

    Serial Displays

    Hazardous Area Annunciators

    Accessories and spares

    Sequential Events Recorders

    A discrete low end unit Omnilog is used in conjuncti on with Omni16 or as a stand

    alone unit for Sequential Events recording up to 128 points. With better than

    1millisecond for 32 inputs and 4 milliseconds for a full 128 inputs. All events are

    logged to integral printer.

    For larger systems requiring better resolution and events streams to SCADA or

    Databases SER260 is used. This is a 32 - 4064 point sequential event recorder with 1

    millisecond discrimination between events designed for critical plant monitoring

    applications.

    Distributed architecture allows multiple outstations and multiple operator display

    points over a wide plant area while still maintaining 1 millisecond accuracy. Events

    streams may be routed to SCADA/DCS or Database packages using the Conet Local

    Area Network and OPC server for Windows.

    Alarm Management Packages for PC

    Omni-4000 is a PC based Alarm and Events management system accepting inputs from

    all Conet Fieldbus enabled products and is capable of displaying 4800 points in an Alarm

    Management format. Event Streams from Conet (Time stamped at source) enter the

    Omni-4000 system via the Conet Local Area Network and are stored to database. Alarm

    screens display dynamic alarm statuses while event streams can be viewed as alarm

    lists dynamically or historically.

    Alarm and Events Management

    Omni8/16C Annunciators TUV assessed for IEC61508 SIL 1.

  • 8/10/2019 Br Products cvFr 03

    4/12

    - 4 - Copyright Omniflex

    Distributed Alarm Annunciation Networked

    MaxiLarm is a powerful distributed Alarm Annunciation application on the Maxiflex

    hardware platform with I/O collection points distributed over up to 10km of twisted pair

    cable. Events are time stamped to 10millisecond resolution. Configuration is via PC

    based set-up program connected anywhere on the network.

    Analog Alarm Integration and Logging

    Pumps, fans, motors need protection in the case of component failure and

    information for predictive and preventive maintenance purposes can reduce failures

    and stoppages. Omniwatch logs with date and time stamp trip or alarms for

    maintenance personnel to view on-screen. Integrating Process Indication(In

    engineering Units), Alarm Annunciation, Events Recording, Signal Conditioning,

    Alarm and Trips Omniwatch provides a unique blenb of engineering to the Alarm

    and Events Management Business. Omniwatch is Conet enabled for SCADA/DCS

    data acquisition too.

  • 8/10/2019 Br Products cvFr 03

    5/12

    - 5 - Copyright Omniflex

    Multidrop Point to Point Telemetry Systems on cable

    Conet Squeezer a modular 16 to 64 Point expandable Telemetry system provides point topoint single direction communications on cable. The mode of operation is transmitter and

    receiver pairs(Tx Node and Rx node) to which expander units are added to achieve 64

    points maximum per node. Up to 126 Nodes are allowed on a single cable. The modules

    are DIP switch configured for Network addresses and baud rate.

    Maxitel a Maxiflex RTU based Telemetry Application provides program free Telemetry

    applications on cable. Signals may be transmitted between two Maxiflex Nodes bi-

    directionally e.g. Pump remote stop start with feedback application on the same cable.

    Analog and digital I/O may be transmitted between the nodes. Up to 126 Nodes may

    share the same cable each node capable of supporting 240 inputs or outputs or

    combination of the two.

    RTUs for Data Acquisition

    Maxiflex can be used also as Data Acquisition and Control elements for SCADA/DCS

    systems. No application programs are required for the Remote I/O nodes. All Inputs are

    automatically scanned, conditioned and made available via the Conet Fieldbus Network

    presentation layer to SCADA. Pre-defined data interchanged tables(DITs) are simply

    accessed to read the Inputs. Outputs are written to the field in the same fashion, simply

    writing to the Data Interchange Table from SCADA.

    IEC61131-3 PLCsThe Maxiflex P3 CPUs are specifically designed to enhance the already successful

    Maxiflex RTU / Telemetry System by combining PLC (ISaGRAF IEC61131-3), Remote

    I/O, Analogue Control, PID Control, Auto tune and data handling along with a wide range

    of Network Communication options.

    Radiological Monitoring Systems

    Omniflex provide cost effective radiological monitoring systems. The MaxiflexSystem enables data from Harwell, iCAM or Labimpex Alpha, Beta and Gamma monitors

    located anywhere within buildings or around larger site areas to be monitored by plant

    SCADA systems as well as providing REAL-TIME Alarm management and building

    evacuation logic systems.

    Telemetry and Data Acquisition

  • 8/10/2019 Br Products cvFr 03

    6/12

    - 6 - Copyright Omniflex

    Networking

    Conet Omniflexs Fieldbus Network Provides the communications mechanism forTelemetry and Data Acquisition applications.

    Several Varaints of Conet exist for various communications media or applications:

    Conet - Copper Cabling

    Conet/m Radio Networking

    Conet/p Serial access to Conet via programming Port

    Conet/s Serial full duplex Conet implementation Fibre or Copper

    Conet/e Ethernet TCP/IP

    Using DDE and OPC servers Conet may be used by any windows application to acquire

    and access Conet Data from the field devices.

    Configuration Management Software

    A suite of Configuration Management Tools are available for Omniflex Products like

    Maxiflex and Omni-16C. These windows based Software Tools allows configurations to be

    saved and archived for future use. There are several options available:

    OmniSet Free Software supplied on Distribution CD

    DITView Allows customising of configuration files

    Conet Explorer Suite. Full Suite of Tools, Forth Down Loader, Terminal Access.

    Cable Networking

    Sophisticated Cable Networking can be achieved with Maxiflex with up to 127 Nodes able

    to share a cable. The Conet Fieldbus Nodes can have application programs running to

    perform control functionality or running as Data Acquisition Nodes. Any combination of

    Conet enabled devices can use the Network.

    Packet Radio Networking

    Maxiflex can be used to implement packet Radio networks Conet/m with up to 255Nodes using analogue radios. The modem is built into the Maxiflex CPU controlling the

    radio transmission.

  • 8/10/2019 Br Products cvFr 03

    7/12

  • 8/10/2019 Br Products cvFr 03

    8/12

    - 8 - Copyright Omniflex

    Remote I/O systems

    The modular I/O module based Maxiflex system provides direct signal conditioning for dataacquisition and control applications providing a cost effective front-end for PLC's and DCS

    systems especially in remote locations where the powerful local area networking capabilities

    allow access to data in remote locations that previously appeared to costly to reach

    Signal Conditioning

    This is a 19inch rack based 3U Eurocard signal conditioning system for flexible front-end

    signal conditioning applications where space and power constraints apply. Single unit

    housing options are also available.

    Power Supplies

    The POWERTERM family of Instrument Power Supplies and Battery Chargers provides the

    discriminating user with a professional range of products specifically designed for mounting

    into instrument panels, where space, safety, reliability and ease of use are important

    considerations.

    Features such as universal power input range, plug-in terminals, built-in LED indication, and

    typically 50,000 hours design life, make these products suitable for automation and control

    applications.

    Power Supplies / Battery Chargers

    Combined Power Supply and Battery Charger system with integrated standby battery

    management for small uninterruptible instrument supply applications. Just connect mains

    supply, standby battery and load for an industrial grade standby power supply system. Ideal for

    RTUs, Dataloggers, Alarm Systems, remote field instrumentation, remote access systems

    etc.

    Loop Isolators, Loop Splitters and Repeaters

    The OMNITERM LPI ,LPX, LPR, LPS are current repeaters specifically designed to

    isolate instrument current loops from circulating ground currents that can cause system

    inaccuracies, or at worst, instrument failure. The current applied to the input is repeated

    on the isolated output, and the load present on the output is reflected back to the input.

    No separate power source is required.The OMNITERM LPI,LPX,LPR,LPS are designed to

    be DIN rail mounted.

    The LPI is optimised for lowest volt drop over 4-20mA, while the LPX is optimised for use

    with an extended current range from 0-50mA and load impedances down to zero ohms.The LPR is used as a loop repeater using a separate 24Vdc supply to give more load

    driving capability, The LPS is a loop splitter with separate 24Vdc supply and coverts one

    loop into 2 output loops fully isolated from the input and each other.

    I/O Systems

  • 8/10/2019 Br Products cvFr 03

    9/12

    - 9 - Copyright Omniflex

    Four Wire TransmittersThe Omniterm TxB is a Universal Input Four Wire current loop transmitter, used as a field

    interface for remote instrumentation. The TxB accepts Thermocouples, millivolt, voltage,

    current and 2&3 wire RTD primary sensors. Configuration of the TxB is by a combination

    of DIP switches to configure input connections and span/ranging via PC The TxB is

    intended for mounting as close to the primary sensor as possible and will operate from a

    24V dc supply voltage providing a 4-20mA loop signal loop output. Isolation of 1500V

    between the input circuit and output current loop eliminates ground loops on the input

    wiring, which would normally cause inaccuracies in readings. The inherent characteristics

    of a current loop provide high noise immunity thus ensuring minimal induced error signals.

    FEATURES

    TC/mV/VC/RB universal input in one product

    0-20mA / 0-10V / 0-10mA universal output

    24-30Vdc powered

    Three port isolation to 1500Vac

    Din Rail or Surface Mount

    Narrow 22.5mm module width

    Sensor linearisation standard

    Output overload detection

    Integrates with OMNIFLEX Asset Manager

    Designed to meet IEC 61508 SIL1 criteria.

    Two Wire Transmitters

    The Ampliterm TWTx is a Two Wire 4-20mA transmitter, used as a field interface for

    remote instrumentation. The TWTx accepts Thermocouples, millivolt, voltage, current

    and 2&3 wire RTD primary sensors. The Ampliterm TWTx is intended for mounting as

    close to the primary sensor as possible and will operate from a 12-45V dc loop voltage

    providing a 4-20mA loop signal on a low cost twisted pair or instrumentation cable, thusproviding the benefit of savings in installation and cable costs (particularly thermocouple

    compensation cable). 1500V isolation between the input circuit and output current loop

    eliminates ground loops on the input wiring which would normally cause inaccuracies in

    readings. The inherent characteristics of a current loop provide high noise immunity thus

    ensuring minimal induced error signals.

  • 8/10/2019 Br Products cvFr 03

    10/12

    - 10 - Copyright Omniflex

    Analogue Trip Amplifiers

    The Omniterm TTB is a Dual Trip Amplifier accepting Voltage or Current input signals and

    providing Two Form C (Change-over contact) outputs. Setpoints are set via front panel

    potentiometers. Deadband is set via internal links. The relays can be configured for High

    or Low tripping in energised or de-energised mode to accommodate fail safe operation.

    FEATURES

    Two independent Trip Relay Outputs

    250Vac (30Vdc) 5Amp contact rating

    0-20mA and 0-10V Inputs

    24Vdc Powered

    Monitor points for easy adjustment

    DIN Rail or surface mounting

    Normally Energised/De-energised relays

    Change-over contacts on both relays

    AC Input Signal ConditioningThe Omniterm TAC AC Voltage and Current Module caters for AC measurement off

    Voltage or Current Transformers in the plant or substation. The input measurement is true

    RMS reading of inputs with the current loop output proportional to RMS reading of the

    input.

    Strain Gauge Amplifier

    The Strain Gauge Amplifier accepts 6 Wire Load Cells and provides a transmitter input

    proportion to the Input from the strain gauge. Tare offset, Range/span are configured

    using OmniSet configuration software. An Auto Tare facility input allows the Strain Gauge

    to be incorporated into automated weighing systems.

  • 8/10/2019 Br Products cvFr 03

    11/12

    - 11 - Copyright Omniflex

    Special Function Amplifiers

    The Omniterm TFX Special Function Module caters for analogue computation requirement

    of current loops on a process plant. The Special Function Amplifier is used for

    computation functions like:

    Adder

    Subtractor

    Multiplier

    Divider

    Multiplier/Divider

    Deviation Monitoring

    Linear Integration

    Square Root Integration

    Signal Inversion

    Accepting up to 4 Analogue Input signals with Two Output Signals the functions above

    can be configured using OmniSet configuration Software.

    OmniSet Configuration UtilitySome of the Omniterm B series devices are configurable via PC. This applies in particular

    to universal inputs devices where configuration parameters such as thermocouple and

    RTD types, input ranges or span can be set via the program port on the Omniterm B

    series device. Input connections are set via DIP switch and the unit options like range

    and span are set via the OmniSet PC based utility giving infinite flexibility in choosing

    measuring range, as well as the convenience of setting other parameters for a PC

    environment. An added advantage of the system is the ability to save the Omniterm B

    series units configuration file for future use.

    Omniterm B Series Configuration Tools

  • 8/10/2019 Br Products cvFr 03

    12/12

    - 12 - Copyright Omniflex

    Modbus I/O ModulesThe C2302A, C2303A, Omni16/Modbus Interface Modules are DIN rail mount devices

    powered from 24Vdc. Their function is to acquire input from the existing Omniflex Omni16

    alarm annunciators or auxiliary I/O for computer or SCADA systems via RS232/RS485

    serial communications using the Modbus protocol.The C2302A is equipped with a 20 way

    ribbon header suitable to connect directly to any existing Omni8 or Omni16 Annunciator

    input or lamp repeat socket. The C2303A is equipped with screw terminals for connecting

    up to 16 hard-wired general purpose inputs. This allows general field input to be

    connected to a Modbus Master as remote inputs. Either RS232 or RS485 is selectable

    via choice of pinout on the Db9 connector situated on the front of the unit. Each module

    acts as a MODBUS Slave device in either ASCII or RTU mode, providing a single data

    register where the status of the 16 inputs can be read .Each unit is equipped with a

    single 8 way DIP switch on which the parameters for the Modbus serial port are selected.Using the modules in RS485 mode, up to 32 of these units may be daisy-chained from a

    single Modbus Master. In this configuration, up to 512 I/O (i.e. up to 32 Omni16s) may

    be monitored from a single Modbus Master.

    COPYRIGHT AND PROTECTIVE NOTICES

    1. The Copyright of this document and the associated drawings, is the property of OMNIFLEX and is issued on condition that it is not copied,

    reprinted or reproduced or transmitted in any form or by any means, electronically, photocopying, mechanical or otherwise, nor its contents

    disclosed, either wholly or in part, without the consent in writing of, or in accordance with, the conditions of a contract with OMNIFLEX.

    2. The publication of information in the document does not imply freedom from patent or other protective rights of OMNIFLEX or others.

    3. Although every intention is made to ensure that performance figures and data are accurate the company reserves the right to alter without

    notice any product or specif ication. Performance figures and data must therefore be specifically confirmed by the company before they become

    applicable to any tender, order or contract.

    4. In the case of electrical components, enough data is included in the drawings to allow maintenance of the equipment. However if component

    availability or substitution information is required please consult the factory for assistance, as it is impossible to include data on every

    component in this document.

    5. This product is sold without liability for consequential loss of any description.