Corrective Maintenance Maintenance NWD-115477-03E 6-7 6.1.1 Alarm Management The alarm severity of each failure is indicated by the following alarm level and alarm class. Alarm classes can be modified. Modification is done by Alarm Severity Setting. 6.1.1.1 Alarm Class Critical (CR) : The Critical severity level indicates that a service affecting condition has occurred and an immediate corrective action is required. Such a severity can be reported, for example, when a managed object becomes totally out of service and its capability must be restored. Major (MJ): The Major severity level indicates that a service affecting condition has developed and an urgent corrective action is required. Such a severity can be reported, for example, when there is a severe degradation in the capability of the managed object and its full capability must be restored. Minor (MN): The Minor severity level indicates the existence of a non-service affecting fault condition and that corrective action should be taken in order to prevent a more serious (for example, service affecting) fault. Such a severity can be reported, for example, when the detected alarm condition is not currently degrading the capacity of the managed object. Warning (WR): The Warning severity level indicates the detection of a potential or impending service affecting fault, before any significant effects have been felt. Action should be taken to further diagnose (if necessary) and correct the problem in order to prevent it from becoming a more serious service affecting fault. Submission Prohibited NEC Internal Use Only

Alarmes_ipaso400

Embed Size (px)

DESCRIPTION

Alarmes_ipaso400

Citation preview

Page 1: Alarmes_ipaso400

Corrective Maintenance

Maintenance NWD-115477-03E

6-7

6.1.1 Alarm Management The alarm severity of each failure is indicated by the following alarm level and alarm class. Alarm classes can be modified. Modification is done by Alarm Severity Setting.

6.1.1.1 Alarm Class

Critical (CR) : The Critical severity level indicates that a service affecting condition has occurred and an immediate corrective action is required. Such a severity can be reported, for example, when a managed object becomes totally out of service and its capability must be restored.

Major (MJ): The Major severity level indicates that a service affecting condition has developed and an urgent corrective action is required. Such a severity can be reported, for example, when there is a severe degradation in the capability of the managed object and its full capability must be restored.

Minor (MN): The Minor severity level indicates the existence of a non-service affecting fault condition and that corrective action should be taken in order to prevent a more serious (for example, service affecting) fault. Such a severity can be reported, for example, when the detected alarm condition is not currently degrading the capacity of the managed object.

Warning (WR): The Warning severity level indicates the detection of a potential or impending service affecting fault, before any significant effects have been felt. Action should be taken to further diagnose (if necessary) and correct the problem in order to prevent it from becoming a more serious service affecting fault.

Submission Prohibited NEC Internal Use Only

Page 2: Alarmes_ipaso400

Corrective Maintenance

NWD-115477-03E Maintenance

6-8

6.1.2 Alarm and Status Indication Detail

6.1.2.1 ODU Alarms & Status

Indication Category Descriptions Severity

ODU Alarm Alarm ODU hardware failure. MJ

TX Power Alarm The TX PWR is lower than 3 dB. MJ

TX Input Alarm The TX IF signal become out of range from -29 dBm ± 5 dB.

MJ

RX Level Alarm The reception level becomes lower than -72 dBm ~ -94 dBm level. (It depends on the modulation system and bit rates).

MJ

ODU CPU / Cable Open Alarm CPU of ODU is faulty or IF CABLE between IDU and ODU is broken or is not connected.

MJ

Mute Status Status Indicates the control status of the ODU TX power output. When the TX power is set to Mute, Status is issued.

-

LO REF Alarm Loss of Ref LO signal of ODU. MN

ODU TYPE MISMATCH Alarm Indicate connected ODU type is not supported at iPASOLINK system, or ODU type cannot use in provisioned modulation setting.

MJ

ODU Power Supply Alarm ALM in a case of Power supply interruption to ODU. MJ

Submission Prohibited NEC Internal Use Only

Page 3: Alarmes_ipaso400

Corrective Maintenance

Maintenance NWD-115477-03E

6-9

6.1.2.2 MODEM-A Alarms & Status

Indication Category Descriptions Severity

Unequipped Alarm Reserved and installed optional card is removed from optional slot.

MJ

Type Mismatch Alarm The equipped type of interface is different from configured type.

MJ

Communication

FAIL

Alarm Communication failure of equipment internal control communication.

MJ

Module Alarm Equipment fault MJ

Tx Bus Error Alarm Data communication BUS failure condition in TX direction from MODEM-A Card.

MJ

Rx Bus Error Alarm Data communication BUS failure condition in RX direction from MODEM-A Card.

MJ

RX SW Status Status Radio interface RX SW usage state in Redundant configuration

-

TX SW Status Status Radio interface TX SW usage state in Redundant configuration

-

LOF Alarm Loss of Frame at radio side. MJ

Frame ID Alarm Frame ID (route differentiation ID) MJ

High BER Alarm Radio signal degradation (High BER threshold detection). (Threshold :1E-3/1E-4/1E-5)

MJ

Low BER Alarm Radio signal degradation (Low BER threshold detection). (Threshold. :1E-6/1E-7/1E-8/1E-9)

MN

Early Warning Alarm Radio signal degradation (Early Warning threshold detection). (Threshold :1E-9)

MN

MOD Alarm Indicates the operating status of the MOD. When any failure occurs in the modulator section, “Alarm” is issued.

MJ

IF Cable Short Alarm IF cable between IDU - ODU is in short condition. MJ

XIF Alarm XIF cable connection error between XPIC master and slave MODEM cards

MJ

InPhase Status In - Phase indicates the received signal DADE status between No.1 and No.2 MODEM interfaces are in Phase condition. In this condition, hitless switch over is available.

-

L2SYNC Loss Alarm Loss of frame synchronization of GFP frames on MODEM port.

MJ

RDI Alarm RDI indication reception alarm on MODEM port WR

UAE Alarm UAE alarm. Indicates the occurrence of an Unavailable state. WR

XPIC Mode Mismatch

Alarm XPIC configuration of two MODEMs is not configured as Master-Slave.

MJ

TDM / AMR Range

Mismatch

Alarm Mismatch condition when the mapping number of E1 channels are different between TX and RX modem ports or mismatch condition of selected RX AMR modulation range and TX AMR modulation range.

MJ

Submission Prohibited NEC Internal Use Only

Page 4: Alarmes_ipaso400

Corrective Maintenance

NWD-115477-03E Maintenance

6-10

Indication Category Descriptions Severity

ATPC Power Mode Status ATPC control signal fault (90sec) as well as MAX Power continuation 90sec.

-

TX SW Reverse Request

Status TXSW request signal receiving condition from the opposite station:

-

TX SW Lock-in Status

Status TXSW Lockin state -

Unlocked Alarm Wireless synchronization status of the local side. MJ

MODEM Power Supply Alarm

Alarm Indicate power off condition of power switch which is in front of MODEM-A card.

MJ

6.1.2.3 STM1-A Option Card Alarms & Status

Indication Category Descriptions Severity

Unequipped Alarm Reserved and installed optional card is removed from optional slot.

MJ

Type Mismatch Alarm The equipped type of interface is different from configured type.

MJ

Communication FAIL Alarm Communication failure of equipment internal control communication.

MJ

Module Alarm Equipment fault MJ

Tx Bus Error Alarm Data communication BUS failure condition in TX direction from STM1-A Card.

MJ

Rx Bus Error Alarm Data communication BUS failure condition in RX direction from STM1-A Card.

MJ

APS Online Status Status APS line protection online status indication -

SFP Type Mismatch Alarm Mismatch between SFP on LCT and installed SFP. MJ

SFP Removed Alarm A SFP is removed. MJ

STM-1 LOS Alarm LOS detection on STM-1 Optical port. MJ

TF Alarm Transmit Failure detection on STM-1 optical port. MJ

RS LOF Alarm SDH Frame synchronization lost in RS (Regenerator Section) on STM-1 port.

MJ

RS TIM Alarm Trace Identifier Mismatch detected in RS (Regenerator Section) on STM-1 port.

MJ

RS EXC Alarm B1 Byte error occurrence in RS (Regenerator Section) on STM-1 port.

MJ

RS DEG Alarm B1 byte error in RS (Regenerator Section) (RS - Degraded) on STM-1 port.

MN

MS AIS Alarm AIS detection in MS (Multiplex Section) on STM-1 port.

MJ

MS RDI Alarm Remote Defect Indication reception in MS (Multiplex Section) on STM-1 port.

MJ

Submission Prohibited NEC Internal Use Only

Page 5: Alarmes_ipaso400

Corrective Maintenance

Maintenance NWD-115477-03E

6-11

Indication Category Descriptions Severity

AU AIS Alarm AIS detection in AU (Administrative Unit) on STM-1

port.

MJ

AU LOP Alarm Loss of AU pointer happens on STM-1 port. MJ

HP UNEQ Alarm HOP (Higher Order Path) Unequipped occurrence on STM-1 port.

MJ

HP TIM Alarm HOP (Higher Order Path) Trace Identifier mismatch occurrence on STM-1 port.

MJ

HP PLM Alarm Payload Label Mismatch occurrence in HOP (Higher Order Path) on STM-1 port.

MJ

HP RDI Alarm RDI (Remote Defect Indication) reception in HOP (Higher Order Path) on STM-1 port.

MJ

LOM Alarm Loss of Multi-Frame on STM-1 port. MJ

TU AIS Alarm In TU (Tributary Unit), AIS detection on STM-1 port. MJ

TU LOP Alarm Loss of TU Pointer on STM-1 port. MJ

LP UNEQ. Alarm LP (Lower Order Path) Unequipped occurrence on STM-1 port.

MJ

LP RDI Alarm Remote Defect Indicate reception by an LP (Lower Order Path) on STM-1 port.

MJ

LP PLM Alarm Payload Label Mismatch Failure occurrence by an LP (Lower Order Path) on STM-1 port.

MJ

ALS Status Indication of automatic laser shutdown condition at STM-1 optical port.

-

RS UAS Status Status UAS status indication on STM port (Repeater Section)

-

STM-1 AIS Generated Status AIS generation condition on STM port. -

PJE Status Pointer justification Event indication at STM port. -

6.1.2.4 16E1-A Option Card Alarms & Status

Indication Category Descriptions Severity

Unequipped Alarm Reserved and installed optional card is removed from optional slot.

MJ

Type Mismatch Alarm The equipped type of interface is different from configured type.

MJ

Communication FAIL Alarm Communication failure of equipment internal control communication.

MJ

Module Alarm Equipment fault MJ

Tx Bus Error Alarm Data communication BUS failure condition in TX direction from 16E1-A Card.

MJ

Rx Bus Error Alarm Data communication BUS failure condition in RX direction from 16E1-ACard.

MJ

Submission Prohibited NEC Internal Use Only

Page 6: Alarmes_ipaso400

Corrective Maintenance

NWD-115477-03E Maintenance

6-12

Indication Category Descriptions Severity

E1 LOS Alarm No signal input on E1 port MJ

E1 AIS Alarm / Status

PDH – AIS ALARM/Status category can change according to "

AIS Received Condition Setting

MJ / -

Usage Error Alarm Unused E1 CH input signal detection. MN

E1 AIS Generated Status AIS generation condition on every E1 Channels. -

6.1.2.5 AUX-A Option Card Alarms & Status

Indication Category Descriptions Severity

Unequipped Alarm Reserved and installed optional card is removed from optional slot.

MJ

Type Mismatch Alarm The equipped type of interface is different from configured type.

MJ

Communication FAIL Alarm Communication failure of equipment internal control communication.

MJ

Module Alarm Equipment fault MJ

Tx Bus Error Alarm Data communication BUS failure condition in TX direction from AUX-A Card.

MJ

Rx Bus Error Alarm Data communication BUS failure condition in RX direction from AUX-A Card.

MJ

Item Name (Input-x)

Item Name (Cluster-x)

Status/

Alarm

HKA Status Indication {Alarm, Normal} for every HKA input.

- or

Severity selectable

Item Name (Output-x) Status HKC Status {Alarm, Normal} for every HKC output. -

Submission Prohibited NEC Internal Use Only

Page 7: Alarmes_ipaso400

Corrective Maintenance

Maintenance NWD-115477-03E

6-13

6.1.2.6 GbE-A Option Card Alarms & Status

Indication Category Descriptions Severity

Unequipped Alarm Reserved and installed optional card is removed from optional slot.

MJ

Type Mismatch Alarm The equipped type of interface is different from configured type.

MJ

Communication FAIL Alarm Communication failure of equipment internal control communication.

MJ

Module Alarm Equipment fault MJ

Tx Bus Error Alarm Data communication BUS failure condition in TX direction from GbE-A Card.

MJ

Rx Bus Error Alarm Data communication BUS failure condition in RX direction from GbE-A Card.

MJ

SFP Type Mismatch Alarm Mismatch between SFP on LCT and installed SFP. MJ

SFP Removed Alarm A SFP is removed. MJ

ETH LOS Alarm LOS detection at Optical ETH port. MJ

ETH TF Alarm Transmit Fail detection at Optical ETH port. MJ

LAN LINK Alarm LINK of the LAN Port is disconnected. MJ

Speed & Duplex Status LAN Port setting (Speed&Duplex) -

6.1.2.7 MSE-A Option Card Alarms & Status

Indication Category Descriptions Severity

Unequipped Alarm Reserved and installed optional card is removed from

optional slot.

MJ

Type Mismatch Alarm The equipped type of interface is different from

configured type.

MJ

Communication FAIL Alarm Communication failure of equipment internal control

communication.

MJ

Module Alarm Equipment fault MJ

Tx Bus Error Alarm Data communication BUS failure condition in TX

direction from MSE-A Card.

MJ

Rx Bus Error Alarm Data communication BUS failure condition in RX

direction from MSE-A Card.

MJ

TDM Buffer Underrun Alarm When packets at Ether side of the PWE path are not

received or a problem occurs with received packets.

MJ

Adaptive CLK Status Status Outputs when the adaptive clock state has changed. (Acquired, Acquiring, Holdover)

-

Submission Prohibited NEC Internal Use Only

Page 8: Alarmes_ipaso400

Corrective Maintenance

NWD-115477-03E Maintenance

6-14

6.1.2.8 MC-A4 Alarms & Status

Indication Category Descriptions Severity

Module Alarm Equipment fault MJ

Bus Error Alarm Data communication BUS failure condition. MJ

Unequipped (PS) Alarm Installed Power Supply Card is removed from PS slot.

MJ

Power Supply(PS) Alarm Alarm in case of power failure. MJ

FAN FAIL Alarm FAN failure MJ

Unequipped (FAN) Alarm Installed FAN Unit is removed from FAN slot. MJ

EXT CLK Unequipped Alarm Installed CLK2M Module is removed from Main Card. MJ

EXT CLK Type

Mismatch

Alarm The equipped type of interface is different from configured type.

MJ

IDU CPU Alarm Alarm. IDU CPU Alarm MN

Memory FAIL Alarm Detection of memory failure MJ

USB FAIL Alarm USB memory failure indication WR

Temperature Alarm The temperature is over the threshold MJ

Maintenance Status Maintenance declaration. -

CLK FAIL Alarm Reference Clock Failed. MN

CLK Drift Alarm Reference Clock source Frequency drift condition MN

LTI Alarm Loss of all incoming timing source MJ

CLK Status Changed Status Reference clock change status

(1) (Locked Ref1)

(2) (Locked Ref2)

(3) (Locked Ref3)

(4) Holdover

(5) Freerun

-

SSM FAIL Alarm Received Sync Status Message value is in unstable condition.

MN

Squelch Status The condition of External CLK Output is in squelch condition.

-

EXT CLK LOS Alarm Loss of Signal condition of External clock input. MN

EXT CLK AIS Alarm AIS (Alarm Indication Signal) condition of External Clock input.

MN

EXT CLK LOF Alarm Loss of frame condition of External Clock input. MN

EXT CLK Loop Alarm Indication of EXTERNAL clock input is used as EXTERNAL clock output.

MJ

E1 LOS Alarm No signal input on E1 port MJ

Submission Prohibited NEC Internal Use Only

Page 9: Alarmes_ipaso400

Corrective Maintenance

Maintenance NWD-115477-03E

6-15

Indication Category Descriptions Severity

E1 AIS Alarm /

Status

PDH – AIS

ALARM/Status category can change according to " AIS Received Condition Setting

MJ / -

PPS FAIL Alarm E1 SNCP Path Protection Switch failed MJ

Usage Error Alarm Unused E1 CH input signal detection. MN

E1 AIS Generated Status AIS generation condition on every E1 Channels. -

ETH LOS Alarm LOS detection at Optical ETH port. MJ

ETH TF Alarm Transmit Fail detection at Optical ETH port. MJ

SFP Type Mismatch (ETH)

Alarm Mismatch between SFP on LCT and installed SFP. MJ

SFP Removed (ETH) Alarm A SFP is removed. MJ

LAN LINK Alarm LINK of the LAN Port is disconnected. MJ

Speed & Duplex Status LAN Port setting (Speed&Duplex) -

ETH-OAM LOC Alarm ETH OAM LOC ( Loss of connectivity) is detected on the indicated MEP

MJ

ETH-OAM Mismerge Alarm ETH OAM Mismatch detection notice. MN

ETH-OAM Unexpected MEP

Alarm ETH OAM Unexpected MEP and Ether OAM Unexpected Period detection notice

MN

ETH-OAM RDI Alarm ETH OAM RDI reception detection notice MJ

LLF Message Timeout Status Loss of a conditional signaling in which the LLF control signal should be received continuously from the opposite radio equipment.

LLF Status LLF force a LINKDOWN status. The Ethernet port under "edge" mode becomes LINKDOWN.

-

IDU TOTAL ALM Alarm IDU TOTAL ALM The highest Severity will be reported

6.1.2.9 Radio Traffic Aggregation Link Alarm

Indication Category Descriptions Severity Radio Traffic Aggregation Link

Alarm All of member ports belong to the radio group are down.

MJ

6.1.2.10 ETH GRP Alarm

Indication Category Descriptions Severity

LAG Link Alarm All of member ports belong to the ETH Link Aggregation group are down.

MJ

Submission Prohibited NEC Internal Use Only

Page 10: Alarmes_ipaso400

Corrective Maintenance

NWD-115477-03E Maintenance

6-16/END

6.1.2.11 TCN Alarms

Indication Category Descriptions Severity

RF OFS Alarm Threshold Crossing Notification MN

RF BBE Alarm Threshold Crossing Notification MN

RF ES Alarm Threshold Crossing Notification MN

RF SES Alarm Threshold Crossing Notification MN

RF SEP Alarm Threshold Crossing Notification MN

RF UAS Alarm Threshold Crossing Notification MN

RS OFS Alarm Threshold Crossing Notification MN

RS BBE Alarm Threshold Crossing Notification MN

RS ES Alarm Threshold Crossing Notification MN

RS SES Alarm Threshold Crossing Notification MN

RS SEP Alarm Threshold Crossing Notification MN

RS UAS Alarm Threshold Crossing Notification MN

DMR RS OFS Alarm Threshold Crossing Notification MN

DMR RS BBE Alarm Threshold Crossing Notification MN

DMR RS ES Alarm Threshold Crossing Notification MN

DMR RS SES Alarm Threshold Crossing Notification MN

DMR RS SEP Alarm Threshold Crossing Notification MN

DMR RS UAS Alarm Threshold Crossing Notification MN

MS BBE Alarm Threshold Crossing Notification MN

MS ES Alarm Threshold Crossing Notification MN

MS SES Alarm Threshold Crossing Notification MN

MS SEP Alarm Threshold Crossing Notification MN

MS UAS Alarm Threshold Crossing Notification MN

E1 CV Alarm Threshold Crossing Notification MN

RX Level (MIN) Alarm Threshold Crossing Notification MN

RX Drop Events Alarm Threshold Crossing Notification MN

RX Undersize Pkts Alarm Threshold Crossing Notification MN

RX Fragments Alarm Threshold Crossing Notification MN

RX CRC Alignment

Errors

Alarm Threshold Crossing Notification MN

RX Oversize Pkts Alarm Threshold Crossing Notification MN

TX Collisions Alarm Threshold Crossing Notification MN

Submission Prohibited NEC Internal Use Only